Installation & Owners Manual 2017

Blueridge Owners Manual
11
Document Version: 01/2017
Copyright 2017 Alpine Home Air Products
3
Drill the piping hole in the wall
Choose the location of the piping hole based on the desired left or right
side outlet from the air handler. This hole will need to be large enough
to accommodate the copper lines, multiconductor wire, and drain tube.
Most customers purchase and install a wall sleeve ranging from 2.5” to 3”
in size to accomodate the copper, wiring, and drain tubing. Cut the hole
in the wall using a 2.5” or 3” hole saw.
In order to help the condensate drain through this hole, slant this pip-
ing hole approximately 5-10 degrees downward, by angling your drill as
shown in Img 2.
Img xx Wall Hole drilling diagram
10-15
o
Wall Sleeve
Hole Size
Piping
Seal Hole
Wall
Inside Outside
Img 2 | Side view of hole drilled in wall
Installation of the Indoor Air Handler