Installation & Owners Manual 2017

Blueridge Owners Manual
25
Document Version: 01/2017
Copyright 2017 Alpine Home Air Products
Hex Nut Diameter (in) Tightening Torque (ft-lbs)
1/4 10-13
3/8 25-30
1/2 36-45
5/8 50-60
If the lines are not already insulated, wrap them with insulation and tape
the insulation in place.
5
Wiring the Air Handlers to the Outdoor Unit
Remove the wire clip on the outdoor unit.
Connect the multi conductor control/power wire that is run from the
indoor air handler to the associating terminals on the outdoor unit. Color
coded multiconductor is highly recommended to ensure that the wires
have been connected correctly.
It is essential that the multi conductor control/power wire is connected
to the same connection port as the matching copper lines for each zone.
For example, the air handler with copper lines connected to port A, must
also have the multi conductor control/power wiring connected to terminal
block A.
Installation of a Multi Zone Outdoor Unit
Place the open-ended wrench on the pipe joint and place the torque
wrench on the union nut (compression fitting). Tighten the union nut
according to the chart on the next page: