Copper Line Length Guidelines
Unit Capacity
(BTU’s/Hour)
Min Line Set
Length
Max Line set
Length
Max Height
Difference
9,000 10 Feet 50 Feet 15 Feet
12,000 10 Feet 66 Feet 30 Feet
18,000 10 Feet 82 Feet 30 Feet
24,000 10 Feet 82 Feet 30 Feet
30,000 10 Feet 100 Feet 30 Feet
36,000 10 Feet 100 Feet 60 Feet
Single Zone - 15, 16, 18, 20, and 22 SEER Blueridge Minisplits
Multi Zone - Since several different zones share the refrigerant of a multi-
zone, the maximum line set lengths differ from the single zone systems.
The maximum line set length of any given zone is 66 feet on the multizone,
not to exceed 246 cumulative feet for the system.
Exception: BMKH18DM-16-9W-9W and BMKH21DM16-9W-12W where
maximum line length for each zone is 33 feet.
Copper Line Lengths Guidelines