LM Wall Mount User Manual

4.
1.
drain hose
2.
2.
outlet pipe
tape
Connect wire of indoor unit
Step 7:
hole
power connection
wire
1.
Step 6:
Install drain hose
16
insulating pipe
Bind the joint with tape
insulating pipe
indoor unit.
drain hose
Wrap the indoor pipe and joint of connection
pipe with insulating pipe, and then wrap it
with tape.
outlet
pipe
drain hose
Open the panel, remove the screw on the wiring
cover and then take down the cover.
Connect the drain hose to the outlet pipe of
panel
screw
wiring cover
Hex nut diameter
1/4'' 15~20
3/8'' 30~40
1/2'' 45~55
5/8'' 60~65
3/4'' 70~75
Tightening torque (N
.
m)
NOTE
Add insulating pipe in the indoor drain hose in order
to prevent condensation.
The plastic expansion particles are not provided.
All wires of indoor unit and outdoor unit should be
If the length of power connection wire is insufficient,
For the air conditioner with plug, the plug should be
NOTICE
connected by a professional.
Make the power connection wire go through the
cable cross hole at the back of indoor unit and
then pull it out from the front side.
please contact the supplier for a new one. Avoid e-
xtending the wire by yourself.
reachable after finishing installation.
For the air conditioner without plug, an air switch
must be installed in the line. The air switch should
be all-pole parting and the contact parting distance
should be more than 3mm.