Ultra heat multi-zone ODU user manual

To the power supply
To unit A
connecting
cable
To unit B
connecting
cable
To unit C
connecting
To unit D
cable
connecting
cable
INDOOR UNIT A INDOOR UNIT B
white
(blue)
white
(blue)
black
(brown)
red
(brown)
L2
L1
POWER
L1
L2
(yellow-
green)
green
(yellow-
green)
green
black white
(blue)
red
(brown)
(yellow-
green)
green
black
INDOOR UNIT C
white
(blue)
red
(brown)
(yellow-
green)
green
black
C
INDOOR UNIT D
white
(blue)
red
(brown)
(yellow-
green)
green
black
DBA
2.
3. Fix power connection wire by wire clamp.
4. Ensure wire has been fixed well.
5. Install the handle.
1.
Remove the cable clamp, connect the power
connection cable with the terminal at the row of
connection and fix the connection. The fitting line
distributing must be consistent with the indoor
unit. terminal of line bank. Wiring should meet
that of indoor unit.
Remove the handle at the right side plate of the
outdoor unit (one screw).
Note: The above figures are only intended to be a simple
diagram of the appliance and may not correspond to the
appearance of the units that have been purchased.
BMKH36M23UH
Air switch capacity
60A
An all-pole disconnection switch having a contact
separation of at least 0.11IN in all pole should be
connected in fixed wiring.
Wrong wire connection may cause malfunction of
some electric components.After fixing cable, ensure
that leads between connection to fixed point have
some space.
The connection pipes and the connection wirings
of the unit A, unit B, unit C and unit D must be
corresponding to each other respective.
The appliance shall be installed in accordance with
national wiring regulations.
Air-conditioner
Including an air switch with suitable capacity,
please note the following table. Air switch
should be included magnet buckle and heating
buckle function, it can protect the circuit-short
and overload. (Caution: please do not use the
fuse only for protect the circuit)
BMKH36M23UH
INSTALLER
8
Power cord
L1 L2
ELECTRICAL CONNECTIONS