Owner's Manual Original Instructions Split Type Wall-mounted Air Conditioner Model: BMKH18M23UH BMKH24M23UH BMKH36M23UH BMKH42M23UH Thank you for choosing our product. Please read this Owner’s Manual carefully before operation and retain it for future reference. If you have lost the Owner's Manual, please contact the local agent at 800-865-5931 or visit www.alpinehomeair.com.
In line with the company’s policy of continual product improvement, the aesthetic and dimensional characteristics, technical data and accessories of this appliance may be changed without notice.
Explanation of Symbols DANGER Indicates a hazardous situation that, if not avoided, will result in death or serious injury. WARNING Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation that, if not avoided, may result in minor or moderate injury. NOTICE Indicates important but not hazard-related information, used to indicate risk of property damage.
THE INSTRUCTIONS BEFORE USE GENERAL INFORMATION WARNING ★ When having a burning smell or ★ The power supply must adopt the smoke,please turn off the power supply and contact with the service center. special circuit that with air switch protection and assure it has enough capacity.The unit will be turned on or off according to your requirement automatically,please do not turn on or turn off the unit frequently,otherwise disadvantage effect may be caused to the unit.
NAME OF PARTS GENERAL INFORMATION BMKH18M23UH WARNING If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen. Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.
NAME OF PARTS GENERAL INFORMATION BMKH36M23UH , BMKH42M23UH WARNING If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Be sure to cut off the power supply before cleaning the air conditioner; otherwise electric shock might happen. Wetting of air conditioner may cause the risk of electric shock. Make sure not to wash your air conditioner in any case.
TECHNICAL DATA GENERAL INFORMATION BMKH18M23UH MODE Electrical data Electricity supply Fuse or air switch Minimum power cord section 208/230V,60Hz 35 5.3 A mm 2 Size and clearance L P H L 36.22 in P 14.96 in H 31.10 in BMKH24M23UH MODE Electrical data Electricity supply Fuse or air switch Minimum power cord section 208/230V,60Hz 40 5.3 A mm 2 Size and clearance L P H L 36.22 in P 14.96 in H 31.
ELECTRICAL CONNECTIONS INSTALLER BMKH18M23UH 1. Remove the handle at the right side plate of the outdoor unit (one screw). An all-pole disconnection switch having a contact separation of at least 0.11IN in all pole should be connected in fixed wiring. 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank.
ELECTRICAL CONNECTIONS INSTALLER BMKH24M23UH 1. Remove the handle at the right side plate of the outdoor unit (one screw). An all-pole disconnection switch having a contact separation of at least 0.11IN in all pole should be connected in fixed wiring. 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank.
ELECTRICAL CONNECTIONS INSTALLER BMKH36M23UH 1. Remove the handle at the right side plate of the outdoor unit (one screw). An all-pole disconnection switch having a contact separation of at least 0.11IN in all pole should be connected in fixed wiring. 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank.
ELECTRICAL CONNECTIONS INSTALLER BMKH42M23UH 1. Remove the handle at the right side plate of the outdoor unit (one screw). An all-pole disconnection switch having a contact separation of at least 0.11IN in all pole should be connected in fixed wiring. 2. Remove the cable clamp, connect the power connection cable with the terminal at the row of connection and fix the connection. The fitting line distributing must be consistent with the indoor unit. terminal of line bank.
INSTALLING THE OUTDOOR UNIT INSTALLER Location Caution: Installation Must be Performed in Accordance with the NEC/CEC by Authorized Personnel Only. Install the drain fitting and the drain hose (for model with heat pump only) Use bolts to secure the unit to a flat, solid floor. When mounting the unit on a wall or the roof, make sure the support is firmly secured so that it cannot move in the event of intense vibrations or a strong wind.
MAINTENANCE INSTALLER Use suitable instruments for the refrigerant R410A. Do not use any other refrigerant than R410A. Do not use mineral oils to clean the unit. INSTALLATION DIMENSION DIAGRAM INSTALLER The installation must be done by trained and qualified service personnel with reliability according to this manual. Contact service center before installation to avoid the malfunction due to unprofessional installation.
CHECK AFTER INSTALLATION INSTALLER Check Items Problems Owing to Improper Installation Is the installation reliable? The unit may drop, vibrate or make noises Has the gas leakage been checked? May cause unsatisfactory cooling (heating) effect Is the thermal insulation of the unit sufficient? May cause condensation and water dropping Is the drainage smooth? May cause condensation and water dropping Does the power supply voltage accord with the rated voltage specified on the nameplate? The unit m