L85 Specifications Sheet

85% OIL FURNACES VARIABLE SPEED L85V
Page 5
BLOWER PERFORMANCE DATA
Configuration
Model
Motor
Size
(hp)
Blower
Size
Nozzle
GPH
Temp.
Rise °F
Blower
Speed
Ta p
Heating
CFM@
0.50”
ESP
Cooling
Adjustment
Cooling CFM @ .50 ext static
pressure in. W.C.
Setting
“A”
Setting
“B”
Setting
“C”
Setting
“D”
Upflow / Highboy
L85UF1V67/87E14 1/2 10 x 10
---
--- --- Nom 1400 1200 1000 800
--- --- (+) 1500 1400 1200 1000
--- --- ( - ) 1200 1000 900 650
.50 50 D Tap Setting* 1200 --- --- --- --- ---
.65 50 A Tap Setting* 1500 --- --- --- --- ---
L85UF1V104/118F20 3/4 12 x 11
---
--- --- Nom 2000 1800 1600 1200
--- --- (+) 2000 2000 1800 1600
--- --- ( - ) 1700 1550 1400 1200
.75 60 C Tap Setting* 1550 --- --- --- --- ---
.85 60 A Tap Setting* 1850 --- --- --- --- ---
Basement / Lowboy
L85BF1V67/87E14 1/2 10 x 9
---
--- --- Nom 1400 1200 1000 800
--- --- (+) 1500 1400 1200 950
--- --- ( - ) 1200 1050 860 650
.50 50 D Tap Setting* 1200 --- --- --- --- ---
.65 50 B Tap Setting* 1450 --- --- --- --- ---
L85BF1V104/118F20 1 12 x 10
---
--- --- Nom 2000 1800 1600 1200
--- --- (+) 2100 2000 1800 1350
--- --- ( - ) 1650 1500 1350 950
.75 60 C Tap Setting* 1550 --- --- --- --- ---
.85 60 B Tap Setting* 1730 --- --- --- --- ---
L85BR1V67/87E14 1/2 10 x 9
---
--- --- Nom 1400 1200 1000 800
--- --- (+) 1500 1400 1200 950
--- --- ( - ) 1200 1050 860 650
.50 50 D Tap Setting* 1200 --- --- --- --- ---
.65 50 A Tap Setting* 1550 --- --- --- --- ---
L85BR1V104/118F20 1 12 x 10
---
--- --- Nom 2000 1800 1600 1200
--- --- (+) 2100 2000
1800 1350
--- --- ( - ) 1650 1500 1350 950
.75 60 D Tap Setting* 1450 --- --- --- --- ---
.85 60 B Tap Setting* 1730 --- --- --- --- ---
Note: All units shipped with low fire nozzle
* Required tap to maintain recommended rise.