BPRPHP14 Spec Sheets

HEAT PUMP PACKAGED UNIT PRPHP14
Page 4
HEAT STRIP ELECTRICAL
Model Heater
Unit Supply
Voltage Single
Phase
Input
kW
240V
Circuit 1 240V Circuit 2 240V Single Circuit 240V
Ampacity Breaker Ampacity Breaker Ampacity Breaker
PRPHP1424EP
5kW
240 5 29.5 30 - - 43.4 45
208 3.8 26.1 30 - - 40.0 45
7.5kW
240 7.5 42.6 45 - - 56.5 60
208 5.6 37.4 40 - - 51.3 60
10kW
240 10 55.6 60 - - 69.5 70
208 7.5 48.6 50 - - 62.5 70
15kW
240 15 - - - - - -
208 11.3 - - - - - -
20kW
240 20 - - - - - -
208 15 - - - - - -
PRPHP1430EP
5kW
240 5 31.2 35 - - 47.9 50
208 3.8 27.7 30 - - 44.5 50
7.5kW
240 7.5 44.2 45 - - 61.0 70
208 5.6 39.0 40 - - 55.8 60
10kW
240 10 57.2 60 - - 74.0 80
208 7.5 50.3 60 - - 67.0 70
15kW
240 15 57.2 60 26.0 30 100.0 110
208 11.3 50.3 60 22.6 25 89.6 90
20kW
240 20 - - - - - -
208 15 - - - - - -
PRPHP1436EP
5kW
240 5 31.2 35 - - 49.5 50
208 3.8 27.7 30 - - 46.0 50
7.5kW
240 7.5 44.2 45 - - 62.5 70
208 5.6 39.0 40 - - 57.3 60
10kW
240 10 57.2 60 - - 75.5 80
208 7.5 50.3 60 - - 68.6 70
15kW
240 15 57.2 60 26.0 30 101.5 110
208 11.3 50.3 60 22.6 25 91.1 100
20kW
240 20 - - - - - -
208 15 - - - - - -
PRPHP1442EP
5kW
240 5 33.5 35 - - 53.8 60
208 3.8 30.1 35 - - 50.3 60
7.5kW
240 7.5 46.6 50 - - 66.8 70
208 5.6 41.4 45 - - 61.6 70
10kW
240 10 59.6 60 - - 79.9 80
208 7.5 52.6 60 - - 72.9 80
15kW
240 15 59.6 60 26.0 30 105.9 110
208 11.3 52.6 60 22.6 25 95.5 100
20kW
240 20 59.6 60 52.1 60 131.9 150
208 15 52.6 60 45.1 50 118.0 125