Owners manual

MWS- 808PMO
7
just need enough room for the centering bolts to allow the entire assembly to
raise when a piece of wire goes through the channel and pushes up the entire
cutter assembly. It is generally recommended to set the centering bolts by
unscrewing the centering bolts on both sides of the assembly a few
turns. Then looking down the left (small wire) cutting channels, tap the
housing right or left to get the blades in the center of the channel. Screw the
bolts in evenly from both sides (right and left bolts). Be careful here not to
move the entire assembly. When they are tight against the housings, take
another look down the left channel guides making sure the cutters are still in
the center of the channel groove. If they are not, readjust. Next loosen the
centering bolts by about ½ a turn on both the right and left side. This leaves
just enough of an air gap to allow the cutting assembly to raise, but not travel
too much from right to left. Next tighten the lock nuts. Make sure not to
tighten or loosen the centering bolt on this step by using another wrench to
ensure it doesn’t spin.
PROCESSING WIRE
Ø There is a wire guide in front of the main shaft and blade shaft where the cables will
be manually inserted. See wire input guide diagram below for a general
understanding of what wires can go in certain cutting channels.
Ø The wire input guide will be used as a general starting point for processing wire.
Before processing, it is recommended to collect similar wire types to assist in wire
processing efficiency.
Ø Selecting the correct input to run the wire through can take some time and
experience. The general rule is to start in a much larger wire guides than the wire in
question, run the wire, check the wire. If not cut, step down to a smaller input guide
and try it again. It is a general misconception that the user should put a wire in the
hole that is the exact same size of the wire. This is rarely the case. After a while the
user will know from experience which guide is right for certain wire types.
WIRE TYPE GUIDE
Ø Sheathed flat cable: 0.55” (14mm) x 0.31” (8mm) WxH
Ø Twisted flat cable: 0.31” (8mm) x 0.23” (6mm) WxH
Ø Single-core cable: Dia. Φ0.07” (2mm) Φ1” (25mm)