Installation Guide
Step 4-1: Installing In-hood 600 CFM Blowers Duct Connection Detail: 6” Round
Recommended Duct Size: 6”  |  Minimum Duct Size: 6”
Figure A:
Attach Blower
Unscrew blower plate and 
set to top or rear discharge. 
Screw blower to plate with 
included hardware
Figure B:
Connect Plate Internally
Re-install all mounting 
screws inside of liner.
Figure C:
Connect Plate Externally
Re-install all mounting 
screws outside of liner.
Figure D:
Connect Power Supply
Connect molex connector 
from control box to blower.
Step 4-2: Installing In-hood 1200 CFM Blowers Duct Connection Detail: 10” Round
Recommended Duct Size: 10”  |  Minimum Duct Size: 8”
INSTALLATION INSTRUCTIONS
Figure A:
Attach Blower Plate
Unscrew blower plate and 
set to top or rear discharge. 
Figure B:
Connect Inner Plate
Screw inner plate with air 
divider onto base plate.
Figure C:
Connect Blowers
Install dual 600 CFM 
blowers onto hood with 
included hardware. 
Connect molex connectors 
to blowers.
Figure D:
Install Blowers in Hood
Screw each blower to the 
plate within the liner with 
hardware provided.
9