Water Filter Data

Performance Data Sheet
Models: BS-AP2-200G Use Replacement Cartridge AP2-200G
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53.
Capacity 200 Gallons (757 Liters) Contaminant Reduction Determined by NSF testing.
Substance Reduction
Average
Influent
NSF/ANSI specified
Challenge
Concentration
Avg %
Reduction
Average Product
Water
Concentration
Max Permissible
Product Water
Concentration
NSF Reduction
Requirements
NSF Test Report
Chlorine Taste and Odor
2.1 mg/L
2.0 mg/L ± 10%
97.6%
0.05 mg/L
N/A
≥ 50%
J-00117746
Nominal Particulate Class I,
0.5 to < 1.0 µm
6,866,667
pts/mL
At least 10,000 particles/mL
99.7%
23,417 pts/ml
N/A
≥85%
J-00117747
Asbestos
260 MFL
10
7
to 10
8
MFL; fibers
greater than 10 µm in length
>99%
< 1MFL
N/A
≥99%
J-00126246
Atrazine
0.009 mg/L
0.009 mg/L ± 10%
95.0%
0.0005 mg/L
0.003 mg/L
N/A
J-00117748
Benzene
0.015 mg/L
0.015 mg/L ± 10%
96.6%
0.005 mg/L
0.005 mg/L
N/A
J-00117749
Carbofuran
0.09 mg/L
0.08 mg/L ± 10%
98.9%
0.001 mg/L
0.04 mg/L
N/A
J-00117751
Cyst*
97,500 cysts/L
Minimum 50,000 cysts/L
99.99%
1 cyst/L
N/A
≥99.95%
J-00123282
Lead pH @6.5
0.147 mg/L
0.15 mg/L ± 10%
>99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00126252
Lead pH @8.5
0.150 mg/L
0.15 mg/L ± 10%
99.3%
0.001 mg/L
0.010 mg/L
N/A
J-00126253
Lindane
0.002 mg/L
0.002 mg/L ± 10%
99.1%
0.00002 mg/L
0.0002 mg/L
N/A
J-00126254
Mercury @ pH 6.5
0.006 mg/L
0.006 mg/L ± 10%
96.6%
0.0002 mg/L
0.002 mg/L
N/A
J-00134901
Mercury @ pH 8.5
0.006 mg/L
0.006 mg/L ± 10%
92.6%
0.0005 mg/L
0.002 mg/L
N/A
J-00126251
P-Dichlorobenzene
0.187 mg/L
0.225 mg/L ± 10%
>99.8%
0.0005 mg/L
0.075 mg/L
N/A
J-00126248
Toxaphene
0.014 mg/L
0.015 mg/L ± 10%
93%
0.001 mg/L
0.003 mg/L
N/A
J-00126249
2,4-D
0.222 mg/L
0.210 mg/L ± 10%
94.5%
0.012 mg/L
0.070 mg/L
N/A
J-00126247
* Based on the use of Cryptosporidium parvum oocysts
Service Flow
0.5 gpm (1.89 lpm)
Water Supply
Potable Water
Water Pressure
20 -125 psi (138 862 kPa)
Water Temperature
33º F - 100º F (0.6º C 37.8º C)
It is essential that the manufacturer’s recommended installation, maintenance and filter
replacement requirements be carried out for the product to perform as advertised. See
Installation Manual for Warranty information.
Note: While the testing was performed under standard laboratory conditions, actual
performance may vary. Contaminant reduction testing is conducted every five years by
certifying agency to maintain certification.
Replacement Cartridge: AP2-200G.
For estimated cost of replacement elements please call
1-800-222-7880. Replacement filters can be purchased at original point of sale.
.
NSF is a trademark of NSF International.
© 2016 3M Company. All rights reserved.
34-8719-7336-7 799669
WARNING
Read entire manual. Failure to follow all guides and rules could cause personal injury or
property damage.
Check with your local public works department for plumbing codes. You must follow their
guidelines as you install the water filtration system.
Your water filtration system will withstand up to 125 pounds per square inch (psi) water
pressure. If your house water supply pressure is higher than 80 psi, install a pressure
reducing valve before installing the water filtration system.
To reduce the risk associated with the ingestion of contaminants:
DO NOT use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system. Systems certified for cyst reduction may
be used on disinfected water that may contain filterable cysts.
NOTICE
To reduce the risk associated with water leakage or flooding:
Read and follow Use Instructions before installation and use of this system.
Change the disposable filter cartridge at the recommended interval; the disposable
filter cartridge MUST be replaced every 6 months or sooner.
Failure to replace the disposable filter cartridge at recommended intervals may lead to
reduced filter performance and failure of the filter, causing property damage from water
leakage or flooding.
System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of
substances listed below

Summary of content (1 pages)