AC300 Portable Power Station Please read this manual before use and follow its guidance. Keep this manual for future reference.
021-01-10 10:54:30 Homepage 120 12 00 W PV Settings Data Alarm 0 W 20% 0 W 0 W Grid DC Load AC Load DC OFF AC AC OFF OFF User Manual Please read this manual before use and follow its guidance. Keep this manual for future reference.
Contents 01. AC300 INTRODUCTION ........................... 01 02. GENERAL SAFETY INSTRUCTIONS ............ 02 03. IN THE BOX ........................................... 05 04. APP USER GUIDE ................................... 07 05. FEATURES OF AC300 ............................... 11 06. STARTUP & POWER OFF ........................... 11 07. USER INTERFACE ................................... 12 08. HOW TO RECHARGE AC300+B300 (INPUT) .. 19 09. DISCHARGE (OUTPUT) ............................ 25 10. UPS ...
01. AC300 INTRODUCTION 1.1. Introduction ● The AC300 uses a dual-core controller (ARM controller + DSP controller) which combines digital and analog signals perfectly to manage and control the MPPT module, the AC Inverter module which uses a bidirectional topology supporting AC reverse fast charging, and the DC-to-DC module. The AC300 does not have a built-in battery pack, requires at least one B300 connected, and supports up to four B300 battery packs connected.
● PV: Solar Panel(s) Charging (Photovoltaic) ● Grid: Home Power Supplied by Utility ● T500: 500W Charger ● DOD: Depth of Discharge ● ECO Mode: A power saving mode for the AC300+B300. The AC output ports are automatically turned off if the load is less than 30W over a span of 4 hours. 02. GENERAL SAFETY INSTRUCTIONS Please read this manual before operating.
2.1. Installation (for grid-tie system) ● Before touching any conductor surface or terminal, measure the voltage of the contact point to confirm that there is no danger of electric shock. ● After the equipment is installed, empty packaging materials such as cartons, foam, plastic, cable ties, etc. should be removed from the equipment area. ● Except for those who operate the equipment, please keep others away from operating AC300.
precautions and grasp the correct method of operation. ● Trained personnel: personnel who have undergone corresponding technical training and have the necessary experience to be aware of the danger that may be brought to him during the operation, and can take measures to reduce the danger to himself or other personnel to at the lowest limit. ● The replacement of equipment or parts (including software) must be done by professionals or authorized personnel. 2.1.3.
● If liquid is found inside the device, user must turn off the power immediately. ● The equipment room must be properly insulated and the walls and floors must be damp-proof. 03. IN THE BOX Standard Accessories No. Category Quantity 1 1 AC300 Power Station 2 AC Charging Cable 1 (15A Charge the AC300 with B300) 3 Multifunctional DC Charging Cable 1 Car Charging Cable 1 For solar, car, lead-acid battery charging. 4 Charging AC300+B300 with cable No3.
Additional Purchase Accessories Sold on BLUETTIPOWER.COM No. 8 Category 30A Charging Cable Full speed charging from L14-30 receptacle. 9 Lead-acid Battery Charging Cable Charging AC300+B300 via Lead-acid battery. 10 PV Drop Down Module(D300S) Connect to rigid panels. 11 12 13 12V/30A XT60 to Aviation Plug XT60 to SPC45 For 30A DC Output To support DC power supply for RV. 100W USB-C to USB-C To charge electronics with USB-C port.
04. APP USER GUIDE Please make sure the Bluetooth & Wi-Fi State is “ON” (set on touchscreen of AC300) before connecting AC300+B300 to BLUETTI App. ( Main Interface - Settings - Next - Next - Next ) Step 1: ● Search for “BLUETTI” in the App Store (for iOS devices) or Google Play (for Android devices) to download the BLUETTI App to remotely control your AC300+B300. The AC300+B300 system can be controlled via either Bluetooth or Wi-Fi.
● Check your email account you used in the BLUETTI App for the verification code sent from BLUETTI server and fill in the activation code located within the email to activate your BLUETTI account. Step 2: ● Connect AC300 with B300. Scan the unique QR code on AC300 to add the unit on the available device list on the App, and fill it with the password of your 2.4GWi-Fi network to activate the communication function of AC300 for data syncing.
Please tap ‘’settings-product info’’ on AC300 to view the SN number of your unit. ● The basic information can be viewed after the unit is connected with App successfully. Tap ‘’gear icon’’ to customize the current working mode and parameters of your AC300 under “Settings”. ● The BLUETTI App supports a “Firmware Update” function which allows access to the latest software upgrades for continued features, improvements and fixes.
Note: Please keep your phone 5m/16.4ft within the AC300+B300 for a better connection during update. User cannot turn on AC300 via BLUETTI App. Also, if BLUETTI APP fails to connect to the Internet. Tap "Settings" on the mainpage of your phone and scroll down until the BLUETTI App shows up(IOS). Tap "Settings" on mainpage of your phone, tap “Application Management” and select BLUETTI(Android). Tap the BLUETTI icon and verify that "Wireless and Data" permissions are enabled.
05. FEATURES OF AC300 01 08 02 09 03 10 04 11 05 12 06 13 07 14 24V/10A Cigarette Lighter Port Wireless Charging Pad 12V/30A Port Power Button LCD Screen USB-C(PD3.0 protocol supported) USB-A (fast charging) Battery connection port USB-A AC Input Port AC Output Port(20A MAX) DC1/DC2 Input Port AC Output Port(30A MAX) Communication Interface 06. STARTUP & POWER OFF ● Connect AC300 with B300. Please follow the steps on B300 User Manual.
button indicator will illuminate. ● Power Off AC300: Long press the power button. The power button indicator light will turn off. ● DC power switch and AC power switch are accessible via the Touchscreen LCD. Press the “DC ON/OFF” button and/or “AC ON/OFF” button on the screen to turn ON/OFF the DC/AC output. ● AC300+B300 will turn on automatically from Power Off status when either grid charging and/or PV charging is applied to the unit. ● User can also power ON/OFF of the system by turning ON/OFF B300.
a . Homepage g. Date/Time b. Settings h. DC load Information c . Data i . DC ON/OFF d. Alarm j . AC ON/OFF e . PV Charging Information k . AC load Information f . BMS Information l . AC Charging Information 7.2. Settings ● You can customize the working mode of AC300+B300 and tweak the parameters such as language, voltage, frequency, current (UPS In-Grid Mode), working type, date/time, etc. ● Click the Settings Button in the homepage to enter the setting interface. 7.2.1.
DC1 PV+/PV- Can be set on screen: (Mainpage Settings - DC1/DC2 Input Source) DC2 PV+/PV- (Cable No.3) 7.2.3 Language Setting & ECO Mode ● Press “English” or “Japanese” icon to set as the system language display of your AC300. ● ECO: The power saving mode of the unit to turn off the AC output to conserve energy if the AC load is less than 30W over 4 hours.
7.2.4. Machine Type (for split phase setting, exclusive for 100-120V Version) *1 NEMA L14-30 receptacle, 30A *2 NEMA TT-30 receptacle, 30A *4 Standard AC receptacle, 20A (Split Phase for *2 AC300 + B300) 7.2.5. Working Mode Tip: The AC300+B300 defaults to Standard UPS Mode. There are 4 working modes you can select in settings: Standard UPS Mode: Default working mode. Time Control UPS Mode: Suitable for areas with peak and off-peak time-of use rates in order to save money.
Note: Only take effect when AC300 has been connected into grid. The value presets at 15A. Email the render for safety password to unlock the Max. grid input current limit. 7.2.7. Date and time & Touch Sound & Backlight Brightness ● Tap each respective date and time setting in order to set the date and time as applicable to your local time zone. ● Tap to Enable/Disable touch sound. ● You may change the Backlight Brightness of the LCD by using the slider on the screen. 7.2.8.
7.3. Data In the Data section, you can check the Battery Status of B300, Product Info, Inverter & Charger Info, and Alarm/Fault History. 7.3.1. Product Info ● When you select the “Product Info” button, you can view the product model, serial number (SN), control software version, monitoring software version, BMS monitoring software version and display software version. ● The Serial Number (SN) can also be used to pair to BLUETTI APP manually.
7.3.2. Inverter & Charger Info By tapping the “Inverter & Charger Info” button, user can view the PV charging, adapter charging, DC output and AC output working status. This section can also be accessed directly from the shortcut icon on the homepage. 7.3.3. Battery Information By tapping the “Battery Information” button, user can view the live information of the status of the B300 battery pack.This section can also be accessed directly from the shortcut icon on the homepage. 7.3.4.
08. HOW TO RECHARGE AC300+B300 (INPUT) ● The AC300 includes two charging ports which can be recharged in different methods . They will be covered in three different sections according to which port(s) are being connected. ● The two ports are named as Aviation Charging Port 1 [CP1] and Aviation Charging Port 2 [CP2]. Wind Turbine By using BLUETTI Wind Turbines, an ultraconnect, highly efficient wind charger lets you harness the wind to rapidly recharge the AC300+B300.
8.1.1. Charging Method 1: From Wall Outlet (by AC charging cable) Connect the AC300+B300 from CP1 via the AC charging cable to the wall outlet @1500W/100Vac, @1800W/120Vac Max. The charging process will automatically stop when it reaches 100% capacity. Additionally, you can choose to access the BLUETTI Sub Panel or the L14-30 receptacle, the maximum charging power allowed will be up to 3000W. DO NOT charge the JP/US version(100-120V) AC300+B300 through 220240V circuit.
nd 8.2. CP2 (2 Charging Port) Pin1:DC1 PV+ Pin2:DC2 PV+ Pin3:DC1 PVPin4:DC2 PV- Pin1 Pin2 Pin3 Pin4 8.2.1. Charging Method 3: Solar Panels (via 4pin aviation-MC4 cable) ● For regular solar panels: The AC300+B300 supports two PV inputs. Each individual input supports up to 12A and the charging voltage should be between 12-150V. The AC300+B300 can achieve a combined maximum of 2400W of total solar input. a. User can connect solar panels in series(Figure 1). b.
● If you choose roof/rigid panels to be the solar power source to charge your AC300+B300, user can easily connect your rigid panels with the MC4to-Aviation cable to your AC300+B300. The optional PV Module (additional accessory) is required to step down the voltage if the open circuit voltage produced by your roof panels exceeds the limit of AC300 can handle: 12150VDC, 12A*2. Note: This PV module doesn’t work with solar panels that have built-in microinverters, and open circuit voltage over 550V.
8.2.3. Charging Method 5 :Charging via Lead-acid battery ● Connect to the positive and negative poles of the battery through the provided solar charging cable(pay attention to distinguish the positive and negative poles of the battery, the red clamp indicates the positive pole, and the black one indicates the negative pole) . ● Tap “setting” at homepage to set DC1/2 input source to “Others” to charge from lead-acid battery. 8.3.
CP1 Charging Port Select: Method 1: GEN charging cable Method 2: AC charging cable CP2 Charging Port Select: DC Input1: Method 3: Solar panels (DC Input Source 1, Select PV on the touchscreen) Method 4: T500 charging adapter (DC Input Source 1, Select Others on the touchscreen) Method 5: 12V Car Charger/Storage battery (DC Input Source 1, Select Others on the touchscreen)Method 6: 24V Car Charger/Storage battery(DC Input Source 1, Select Others on the touchscreen) DC Input2: Method 7: Solar panels (DC In
Method 11:PV Parallel ( PV parallel needs to be enabled on the touchscreen) 8.4. How to calculate the recharging time of AC300 E.g. : The total recharging power is 5400W(3000W+2400W) recharged by AC and 2nd PV at same time, the estimation time will be 1.6-2.1Hrs.(AC300 with two B300 in parallel) 09. DISCHARGE (OUTPUT) The running time of the AC300+B300 is subject to factors such as ambient temperature, discharge rate, remaining battery capacity, altitude and other factors. 9.1. The Output Port 9.1.1.
EU Version 6 * 220-240V/20A JP/US Version 7 * 100-120V/20A Only the NEMA TT-30 can generate 3000W,30A power of output, the standard AC output port can produce 2000-2400W,20A power of output. UK Version 6 * 220-240V/20A AU Version 6 * 220-240V/20A 9.1.2. DC Output Port 1 2 3 1. *1 RV port 4 2. *1 24V/10A Cigarette Lighter Port 3. *1 USB-C (PD 100W) 4. *1 Power button 5. *2 USB-A (fast charging) 6.
9.2. Operation Time Estimation AC300 + B300*2 = 6144Wh ●Kitchen Equipment Refrigerator 700W(24h) 2.8 Day Electric Fry Pan 1500W 3.3 Hrs Microwave Oven 1000W 5.0 Hrs Washer 500W(1000W) 4.8-9.2 Hrs Air Conditioner 8000Btu 2 Hrs Smart Phone 18Wh 115 Times Laptop 45Wh 71 Times Welding Machine 1800W 2.8 Hrs Circular Saw 1400W(2300W) 2.1-3.5 Hrs ●Home Equipment Space Heater 1500W 3.2 Hrs Desktop 300W 14.5 Hrs ●Tools Bench Grinder 1400W 3.5 Hrs ●Transportation Electric Vehicle(16A) 1800W 13.
9.3. How to Calculate the Operation Time ●What is the depth of discharge (DoD)? To extend the battery-life, the power station set the 90% DOD, which means that only 90% of the battery capacity can be discharged. 10% of the energy is reserved to avoid damage to the battery due to over-discharge. η indicates local inverter efficiency. DOD=90%, η =90%. 10. UPS 10.1.
Non-critical Load ≥ 3000W Grid BLUETTI Main Panel Sub Panel AC300 BLUETTI PV Module Solar Panel Critical Load ≤3000W ( AC300 grid-tied home power back-up system with Sub Panel and roof panels ) 1 2 3 ( Plug-in UPS system ) Step1: Plug the AC charging cable into the wall outlet. Step2: Plug the AC charging cable into the AC input port.
●The default working mode is “Standard UPS Mode”. 10.2. Enable UPS Running Mode 10.2.1 Standard UPS Mode ● The AC300+B300 will power your load directly from the grid and maintain a 100% charge. When grid power fails, the AC300 switches to internal batteries. 10.2.2. Time Control UPS Mode ● Set the times of the AC300+B300 to be charged via grid power and the times to run loads from its battery.
10.2.3. PV Priority UPS Mode ● PV Priority Mode: Recommended for areas with stable grid power. The battery will be recharged mainly by PV for power savings. ● Note: In PV Priority Mode, AC300 can only be recharged via grid to 30% capacity, and also discharge to 30% of the capacity (you can tweak it to 100% for full grid charging manually on touchscreen or App) as the "Reserved capacity for PV charging". And rest of the capacity will be fully charged from either solar power or 2 adaptors.
10.2.4. Customized UPS Mode ● Charge/Discharge time, and High/Low Battery SOC can be set in this UPS mode. ● Ability to disable the grid charging. The unit will not charge batteries from grid. ● Apart from Time Control UPS, the main switch of grid charging and time mode settings are involved. The setting of "Time Setting" and "SOC Setting" will take effect on both PV Priority Mode, and Time Control Mode. 11.
Just Power On Note: (1) Please disconnect the AC charging cable for both AC300 units while binding into Fusion Box Pro. (2) Certificated Technician is required to build the split phase system to power the Sub Panel. Warning: If you insist to charge the AC300 which has been connected into Fusion Box Pro already, please make sure the L1/L2/N wire is set at the right phase sequence or the AC300 will be damaged.
X(L1) W(N) Y(L2) G(PE) L1 PE L2 N AC Input Cable(L14-30) L2 N PE L1 N PE WRONG CONNECTION It`s forbidden to charge AC300+B300 through the original AC charging cable in Split Phase System, please use Fusion AC Input Cable(Optional Purchase) to charge the two set of the AC300+B300 in Split Phase System. Wrong Connection will damage the power station and your warranty will be invalid, BLUETTI will not take responsible for the damage caused by personal negligence or wrong operation.
● The “Machine Type” setting on screen is used to enable or disable Split Phase output. Split-Phase output is achieved by bonding two AC300 into one power system to double the available output power, voltage, and capacity. ●“Split Phase” is only used for connecting both *2 AC300 together (exclusive for the 100-120V version of the AC300). A Fusion Box(P30A) is required (sold separately).
12. TECHNICAL SPECIFICATION Model AC300-JP AC300-US AC300-EU/UK/AU Net Weight 21.6kg (47.62lbs) Dimensions 520*320*358mm (20.5*12.5*14.1in) Charge Temperature 0-40℃ (32-104 ℉ ) Discharge Temperature -20-40℃ (-4-104 ℉ ) Storage Temperature -20-40℃ (-4-104 ℉ ) Working Environment 10-90% Humidity Certification PSE, FCC, CE, UN38.3, msds, UL, SAA and ROHS Capacity 3072-12288Wh (60-240Ah) Battery Type LiFePO4 Standard Battery Voltage 51.2VDC Battery Cell Voltage Range 44.8-57.
Rated Output Frequency 50/60Hz Rated Continuous Power 3000W Rated Output Current 30A 25A 13A 3100W < load < 3750W, 2min; Power of Over-load 3750W < load < 4500W, 5s; 4500W < load < 6000W, 500ms Efficiency >88% THD <5% DC Output Cigarette Lighter Port *1 24VDC,10A USB-A USB-A(fast charging) USB-C (Type-C) *2 5VDC,3A,15W total *2 *1 Wireless Charging Pad RV Port 3.6-12VDC,3A;18W*2 total 5-15VDC,3A;20VDC,5A,100W *2 5/7.
BLUETTI 13. STORAGE AND MAINTENANCE ● Please turn off the unit and charge it to 50-70% capacity every time before storing it. ● To preserve the battery health, please discharge and fully charge the unit at least once every 6 months. ● Ensure proper ventilation in use or store and keep away from any combustible materials or gases. ● Avoid exposing the unit to rain or wet environment, and direct sunlight (32113 ℉ , 0-45℃ ), clean and dry environment is strongly recommended.
008 OCP (Over Current Protection)- Hardware Please contact with the dealer if the error still exists after rebooting the unit. 009 LLC Soft-Start Failure Please contact with the dealer if the error still exists after rebooting the unit. 010 BUS Soft-Start Failure Please contact with the dealer if the error still exists after rebooting the unit. 011 H-BUS Voltage High Please contact with the dealer if the error still exists after rebooting the unit.
022 Inverter Output Short circuit Please disconnect the load to make sure the load has been connected properly. Click to clear the alarm history. Inverter Over-load 023 Protection Please disconnect the load to make sure the output power of loads meet the limit of the unit. Click to clear the alarm history. 024 Phase Integration Error Check the input wire and whether the“Master” unit or “Slave”unit can work well.
056 AC Overload Warning The output power of load exceeds. 057 Grid Voltage High Please check whether the grid voltage fits the input voltage standard of AC300. 058 Grid Voltage Low Please check whether the grid voltage fits the input voltage standard of AC300. 059 Grid Frequency High Please check whether the grid frequency fits the input frequency of AC300. 060 Grid Frequency Low Please check whether the grid frequency fits the input frequency of AC300.
085 RTC Read & Write Error Please contact with the dealer if the error still exists after rebooting the unit. Please disconnect the appliances on DC 086 12V/30A Port OCP 12V/30A ports. Clear the alarm history or restart the unit. 087 24V/10A Port OCP Please disconnect the appliances on DC 24V/10A ports. Clear the alarm history or restart the unit. 088 USB/TYPE-C/PD Port Current High Please disconnect the appliances on USB ports. Clear the alarm history or restart the unit.
097 BMS Temperature abnormal Please store AC300 at the recommended temperature and leave it until the temperature inside back to the normal standard. 098 BMS Over Voltage Please contact with the dealer if the error still exists after rebooting the unit. 099 BMS Low Voltage Please contact with the dealer if the error still exists after rebooting the unit. 100 BMS Over Current Please contact with the dealer if the error still exists after rebooting the unit.
The firmware including ARM, DSP, IoT and BMS can be upgraded online through BLUETTI APP. ● Can it be charged and discharged at the same time? Yes, the unit supports pass-through charging function for both AC and DC outputs. ● What is the UPS switching latency? 20ms from offline UPS. ● Can I connect my two AC300+B300 units with a Fusion Box(P020A) to achieve double the output power, voltage and capacity? Only Fusion Box Pro(P030A) can be connected two set of AC300+B300 power station.
adapters and accessories. ● BLUETTI will not bear all responsibilities if the damage is caused by not operating the product properly according to the instruction of user manual. ● AC300 is not suitable for use on the relevant equipment or machines involving: Personal safety, such as atomic energy devices, aerospace devices, or any equipment or machines that require highly reliable power sources.
FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 0.65ft between the radiator and your body.
Company: POWEROAK GmbH Address: Lindwurmstr. 114, 80337 München Germany Mail: logi@bluetti.de Company: POWEROAK ENERGY UK CO.,LTD Address: Suite 108 Chase Business Center 39-41 Chase Side London United Kingdom N14 5BP Mail:poweroak.eu@bluetti.com P/N:17.0303.