Line Interactive UPS PowerWalker VI 500T/HID PowerWalker VI 750T/HID PowerWalker VI 1000T/HID PowerWalker VI 1500T/HID Quick Start Guide EN
EN
CONTENT IMPORTANT SAFETY INSTRUCTIONS ...................................................... 1 1. Introduction ............................................................................................... 4 2. Description of Features ............................................................................. 4 3. Package Contents .................................................................................... 4 4. Product Overview .....................................................................
IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS – This manual contains important instructions for models PowerWalker VI 500T/HID, 750T/HID, 1000T/HID, 1500T/HID that should be followed during installation and maintenance of the UPS and batteries. This product is specially designed for PCs and it is not recommended for use in any medical equipment, life-supporting system and other specific important equipment.
The internal short circuiting of the UPS will lead to dangers such as electric shock or fire; therefore do not allow liquids or any foreign object to enter the UPS. No water containers (such as a water glass) or any other liquid-containing vessels shall be placed on the top of the UPS so as to avoid such dangers as electric shock. Please do not use the UPS in excess of the rated load capacity. Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Do not dispose of battery or batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. Icon Φ on the rating label stands for phase symbol. This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by laymen.
1. Introduction EN PowerWalker VI series is an intelligent and compact line interactive UPS (Uninterruptable Power Supply) which is designed to protect your personal computer or sensitive electronic equipments from all forms of power interference, including complete power failures. It is equipped with many features that allow any attached equipment to operate longer and more reliability. 2.
4.
III: LCD description: UPS ON AVR mode Battery mode Internal fault Output load level Battery level Input measurements Output measurements Measuring unit EN IV: UPS setting through the LCD: Release scroll down button to select menu Example of setting Save the new value LCD will shut off if there is no activity for 3 minutes. (1) In low sensitivity mode (Lo) UPS will tolerate more fluctuations in power and will go on battery power less often.
5. Installation and Initial Startup EN Before installation, please inspect the unit. Be sure that nothing is damaged. I: Placement & Storage Conditions Install the UPS in a protected area that is free of excessive dust and has adequate air flow around the unit, and is free from excessive dust, corrosive fumes and conductive contaminants. Please place the UPS away from other units at least 20 cm to avoid interference.
EN III: Connect the Loads Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS unit, and devices connected to the UPS will be protected by UPS unit. Do not attach a power strip or surge suppressor to the UPS. IV: Connect LAN cable, Modem or Phone line for Surge Protection Connect for example a single modem or phone line into surge-protected “IN” outlet on the back panel of the UPS unit.
EN NEVER connect a laser printer or scanner to the UPS unit, because in-rush current generated by motor’s devices may cause the damage of the unit. VI: Turn On/Off the Unit Turn on the UPS unit by pressing the On/Off button. Turn off the UPS unit by pressing again the On/Off button.
6. Functions & Operation I: DC Start Function EN DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS. II: Green Power Function These series are equipped with Green Power Function for saving power and protecting battery. The feature of deep discharge protection is adoped on battery mode.
7. Software Installation on your PC Connected by USB to a PC or notebook, the Software enables communication between the UPS and the computer. The UPS software monitors the status of the UPS, shuts down the system before the UPS is exhausted and can remotely observe the UPS via the Network (enabling users to manage their system more effectively). Upon AC failure or UPS battery low, UPS takes all necessary actions without intervention from the system administrator.
8. Maintenance I. General EN The UPS is virtually maintenance free: take care of proper environmental conditions and keep air inlets-outlets free of dust. II. Fuses If the AC input fuse is defect, be sure it is replaced by a compatible fuse from the same make and type. Never short circuit batteries. When working with batteries, remove watches, rings and other metal objects, and only use insulated tools. III. Battery-module replacement Read all safety rules before replacing the battery.
EN C - Remove the metal protection cover in front of the battery (one screw). D - Pull the plastic tab to remove the battery block and replace it. Mounting the new battery module Carry out the above instructions in reverse order. To ensure safety and high performance, use only batteries supplied by BLUEWALKER.
9. Trouble Shooting Symptom No LCD display on the front panel. EN Possible Cause 1. Battery isn’t connected. 2. Battery defect. 3. On/Off button is not pressed. 1.Overload of the UPS. Alarm buzzer beeps continuously when AC 2.Power cord is loose. supply is normal. When power 1. Overload of the UPS. failure, back-up time is 2. Battery voltage is too low. shorten. 3. Battery defect due to high temperature operation environment, or improper operation to battery. Remedy 1. Reconnect battery. 2.
10.