Installation Instructions

System overview
RC66 | 08-2021
8
Blum-Novotest GmbH
3.2 Description
Fig. 3-2 Device description RC66.
3.3 Display elements
7 8 91 34
5
6
2
(1) Mode LED
(2) Status LED
(3) Battery LED
(4) Transmit LED
(5) Receive LED
(6) Fastening hole
(7) Connecting cable
(8) Seal insert
(9) O-ring 40× 2(NBR 70)
Mode LED
Standby
TC, Z-, ZX- – Probe 1
TC, Z-, ZX- – Probe 2 … Probe 6
DIGILOG, RG – Probe 1 … Probe 6
BG – Probe 1 … Probe 16
KOMflex – Probe 1 … Probe 16
Pairing
YE
Status LED
TC, Z-, ZX- – Measuring device home position.
BG – Connection established.
KOMflex – Connection established.
Pairing successful.
TC, Z-, ZX- – Measuring device deflected.
BG – Collision
MG – Collision
KOMflex – Connection failed.
Pairing unsuccessful.
TC, Z-, ZX- – Connection interrupted.
BG – Connection being established/terminated
KOMflex – Connection being established/terminated
Analogue data
Pairing not yet performed.
YE