Product Manual

14
FAULT CODES
The top row first stage LED will flash red when a fault is detected. The LED will
quickly blink the error code, pause for 2 seconds, then repeat for up to 30 seconds.
Touching one of the push buttons while the error LED is flashing will make the unit
re-attempt battery charge immediately.
30 seconds after a fault is detected, the unit will automatically re-attempt battery
charge. After 3 consecutive attempts the unit will remain in the error condition until
power cycled, or the user touches one of the settings buttons.
Faults can be avoided if:
1. Red Clamp is connected to the positive terminal of the battery and Black clamp
to the negative terminal of the battery.
2. Ambient temperature is less than 50°C
3. Output clamps/wires are not shorted with each other.
4. Battery is indeed a 12V battery and/or not faulty.
Indicator Meaning
Solid RED Battery appears to not take a charge current, unknown fault
1 Flash RED Reverse Polarity
2 Flash RED Over Temperature
3 Flash RED Output Short Circuit
4 Flash RED Over Voltage - Battery
5 Flash RED Under Voltage - Battery