Specification Sheet

The illustrations and descriptions herein are applicable to production as of the date of this Technical Data Sheet. B-9806 Issued 5/18/21 Printed in U.S.A.
The manufacturer reserves the right to, and does from time to time, make changes and improvements in designs and dimensions. © 2021 by Bobrick Washroom Equipment, Inc.
SPECIFICATION:
Grab Bar shall be stainless steel with satin finish. Grab bar shall have type 303, 14-gauge (2mm) stainless steel tubing. 1" outside
diameter. Clearance between the grab bar and the wall shall be 1" (38.1mm). Concealed Mounting Flanges shall be 2/5" (10mm)
thick, threaded solid stainless steel with satin finish, 2" (50mm) diameter, equipped with three screw holes for attachment to wall.
Flange Covers shall be 1/8" (3mm) thick, threaded solid stainless steel with satin finish. 2" (50mm) diameter and shall conceal
the mounting screws. Threaded solid pillars shall have 1/8" (6mm) wall thickness, 1" (25mm) outer diameter securing the flange
covers. A metric M8 hex screw, with a curved washer shall connect the grab bar's tube with the flange. Grab bar shall comply with
with accessible design (including ADAAG in the USA ) for structural strength.
Grab Bar shall be Model B-9806 __________ (insert length) of Bobrick Washroom Equipment, Inc., Clifton Park, New
York; Jackson, Tennessee; Los Angeles, California; Bobrick Washroom Equipment Company, Scarborough, Ontario;
Bobrick Washroom Equipment Pty. Ltd., Australia; and Bobrick Washroom Equipment Limited, United Kingdom.
STRENGTH:
Bobrick grab bars that provide 1-1/2" (38.1mm) clearance from wall can support loads in excess of 1,322lbs (600kgs) if properly
installed. Other grab bar configurations can support loads in excess of 250 pounds (113kg) if properly installed, complying with
accessible design (including ADAAG in the U.S.A.) for structural strength.
Safety Warning: Grab bars are no stronger than the anchors and walls to which they are
attached and, therefore, must be rmly secured in order to support the loads for which they
are intended. To avoid potential injury, the building owner or maintenance personnel should
remove the grab bar from service if the grab bar is not adequately secured to wall.
INSTALLATION:
Provide concealed anchor device or backing as specified or required in accordance with local building codes before wall is finished.
Fasten mounting flanges to anchor device or backing. Put flange covers over each mounting flange to conceal mounting screws.
Concealed anchor devices and mounting screws are not included with Bobrick grab bars and must be specified as an accessory.
Place flanges in desired mounting location. Use flange as a template to mark location of mounting screws and drive mounting
screws into the wall at marked locations. Install grab bar on the wall by placing the flange covers onto the flange followed by the
pillars, placed onto the flange covers. Place M8 hex screw with curved washer through the tube's elongate screw holes into the
flange and tighten the screw. Eventually snap the two end-covers onto each of the tube's end.
Note: Recommend use of #10 sheet metal screws or wood screws to install flange.
Important Notes:
1. Dry Wall Mounting Kit — Bobrick offers a mounting kit that allows the FINO-grab bars to be installed in dry walls without
backing. Wall requires minimum 5/8" (16mm thick) painted or tiled dry wall.
2. Glass-Mounting-Kit — Bobrick offers a mounting kit for Glass-partitions (other material is possible as well) for securing the
grab bar from the opposite side of the panel via a "through-fix". Panel-thickness can range from 1/2" to 1-3/8" (12mm-34mm).
3. "Back-to-back" Mounting Kit — Bobrick offers a kit for the installation of two grab bars against each other, being on the
opposite side of the panel. Panel-thickness can range from 1/2" to 1-3/8" (12mm-34mm).
Description
Through-x-set for securing grab bar from opposite side for 1/2" to 1-3/8"
(12mm-34mm) panel thickness - comprising of a through-x-headplate,
PU-washers and grub screws
Mounting Kit No.
9806-21
Mounting Kit No.
9806-20
Description
Consists of a drywall-ange-adapter-kit, part no. 9806-252 and a Wingit™
fastener, part no. 9806-251
Description
Set of PU-washers and grub-screws for back-to-back installation for 1/2" to
1-3/8" (12mm-34mm) panel-thickness
Mounting Kit No.
9806-22