Bogart TM-2030 Specifications and Warranty

Bogart Engineering TriMetric: TM-2030 Warranty and Specifications
Warranty: 4 years provided there are no obvious signs of abuse: We will repair or
replace (at our option) to operate at a level specified or implied by our instructions.
Main battery (B1): Measures Volts, Amps, Watts, Battery % Full, Amp-hours from full, Days since
charged, Timer for days since Equalized. Also data logging (history data) described below.
Secondary Battery (B2) sharing common negative with main battery: Measures volts only
Battery Volts: From 10.0 – 65.0 volts for main battery. From 0.0 to 100 volts on secondary battery.
Resolution 0.1 volt. Accuracy ± 0.3%
Amps charging or discharging: With 500A/50mV shunt: 00.0 to ± 999 Amps, resolution 0.1A. With
100A/100mV shunt 0.00-300 Amps, resolution 0.01 Amp. ±1% ± least significant digit.
Note: Maximum amps is often limited by the shunt capability: maximum current for a typical
500A/50mV shunt is about ±400A. For a 100A/100mV shunt about ±70 Amps. (Depending on
shunt design and ambient temperature)
Watts: ±20,000 Watts. (With 500A shunt: when “Amps” read greater than 10.0, Watts accuracy ±1.5% ±
least significant digit.) When “Amps” value is lower, watts accuracy depends on “amps” resolution
accuracy.
Amp-hours: Measurement accuracy: 0.00 to ±80,000 Amp-hours to same accuracy as amps.
Battery % Full: Measurement accuracy ±1%. Also measures overcharge. Typical system accuracy, if
batteries are charged full at least every 5 days : typical ±4%. With “efficiency” set to suggested
94% the Battery%Full Display will be conservative (i.e. display a little lower than actual).
Shows “replaced amp hours”: Compared with most recent discharge period—while charging shows what
percent of previous amp hours have been replaced.: 0-199%
Meter Power requirement: About 30 mA when display is on and about 16mA when display turned off.
Efficiency factor adjustable: 60-100%
Battery capacity settable 10 to 10,000 Amp-hrs.
Serial Data: 5V output stream with all TriMetric real time data ASCII coded.
Charge criteria defined by: Filtered voltage above Vset. Filtered amps less than Iset. Both adjustable.
(Filtered time constant: 140 seconds). See Section 6.2 of TM-2030 User’s Instructions for detailed
description.
Power Requirement: Power from main battery B1: 9-65V, 32mA with display lighted. 16 mA with
display off.
Size: TM-2030-RV: Box is 4-1/4 high x 3 x 1-3/8 inch depth
with 1/2 in. mounting tabs top and bottom. (10.8 x 7.6
x 3.5 cm.)
TM-2030-A: 4-1/2 x 4-3/4 panel with circuit board 1-1/8 (max) in. deep. (11.4 x 12.1 x 2.85 cm.)
History data: retained in memory when power turned off
Cumulative amps discharged during battery lifetime (0-999,000 amp hours) measures only
dischargeamp-hours, to measure battery wear
Records the following for last 5 charge/discharge cycles:
Hours ago since end of cycle
Length of cycle (hours)
Amp hour efficiency factor for each complete cycle (amp hours total discharging
divided by amp total charginto show charge efficiency of battery system)
Minimum voltage for each cycle.
Minimum battery %Full for each cycle
For the last 5 days:
Maximum charging voltage each day
Amps value: intended to show how close to “charged” the battery system got
When maximum voltage greater than charged setpoint volts: shows minimum amps.
When maximum voltage less than charged setpoint volts: shows amps at maximum
voltage
Maximum value percent charge returned compared to most recent discharge