Analog Door Phone Model ADP1 Installation and Use Manual © 2004 Bogen Communications, Inc. All rights reserved. Specifications subject to change without notice.
Notice Every effort was made to ensure that the information in this manual was complete and accurate at the time of printing. However, information is subject to change. Important Safety Information Always follow these basic safety precautions when installing and using the system: 1. 2. 3. 4. 5. 6. 7. 8. 9. Read and understand all instructions. Follow all warnings and instructions marked on the product. DO NOT block or cover the ventilation slots and openings.
Description The ADP1 is a convenient remote, weatherproof, hands-free two-way terminal device for telephone systems. The unit is telephone line powered and includes adjustable microphone and speaker volume levels as well as a selectable Auto Answer feature to allow for remote monitoring. The ADP1 also includes an adjustable and defeatable call timer and can respond to forward disconnect signals.
Settings ADP1 PC Board 7 NOISE REDUCTION OFF 4 5 1. TEL Line Connector - Analog station line connection (Tip and Ring) is made via an RJ11 connector that is pre-wired to a 2-position pluggable terminal block. The connections to the terminal block are not polarity sensitive. (See Wiring, pg. 5.) 2. Speaker Volume POT - The Speaker Volume POT controls the speaker volume level of the unit. Clockwise rotation (looking at POT) increases the volume. 3.
Wiring Phone Connection The ADP1 comes with an RJ11 wired to the pluggable terminal block. Connect the ADP1 to the phone system’s analog station line programmed for ring down operation using the RJ11 or directly to the screw terminals depending on how the lines are terminated.The connections to the terminal block are not polarity sensitive. Surge Protection To increase surge protection, connect a protective Earth Ground to the spare lug provided.
Installation The ADP1 is designed to fit in most standard dual gang electrical boxes. Make sure to use the proper box type for intended installation (e.g., flush or surface mount, indoor or outdoor location, etc.). Flush Mounting the ADP1 (Indoor/Outdoor) 1. 2. 3. 4. Cut rough opening and install appropriate electrical box. Note: The box must be flush with the surface within 1/16". For outdoor installations, caulk around the box, filling any gaps between the box and the rough opening.
Specifications Power: Timer Duration: Loop Current Loss Disconnect: Ring Voltage: REN: Connections: Dimensions: Product Weight: Telephone line powered (18V DC / 20 mA minimum) 15 seconds to 2 minutes 300 ms minimum 40V AC RMS minimum 0.7A 2-position pluggable terminal block Earth Ground lug 5" W x 5" H x 21/4" D (fully assembled) 45/8" W x 45/8" H x 2" D (aluminum box) 4 lb.
Warranty The ADP1 is warranted to be free from defects in material or workmanship for two (2) years from the date of sale to the original purchaser.Any part of the product covered by this warranty that, with normal installation and use, becomes defective will be repaired or replaced by Bogen, at our option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. The product will be returned to you freight prepaid.