Data Sheet

Architect & Engineer Specifications
The zone paging system shall be the Bogen PCM2000 Zone
Paging System, designed for direct connection to loop start
and ground start trunks, to PBX or KEY paging ports which
supply DTMF capability, and to analog T/R lines. The unit shall
allow total system amplifier power of up to 250W.
The unit shall include flanges with keyhole slots for wall-
mounted installation. Operation shall require a 12V (1.5A) DC
power supply. A suitable power supply shall be provided
(PCMPS2 power supply).
The system shall consist of the appropriate modules as spec-
ified and shall be registered under Part 68 of FCC rules.
Modules
All modules shall be designed for wall-mount installation. All
modules shall be equipped with a ribbon cable and connector
and power cable with connector to permit them to be intercon-
nected to each other. The face plates of each module shall be
finished in black, with each control/connector clearly labeled in
white. Each face plate shall have knockouts to facilitate cable
and wire dressing. All connections shall be made using a small
regular screwdriver or common jacks (RJ11 or RCA).
The following modules shall be available:
PCMTIM - Telephone Interface Module. One PCMTIM module
shall be provided per PCM2000 system. The module shall
provide for telephone interface selection via slide switches.
It shall include a volume control for tone and BGM source, and
RJ11 jacks for Override, Page Port/Trunk, and 90V Night
Ring/Station inputs. A connector block, using screw
terminal connections, shall be provided for BGM source, and
two (2) C-form relay contact sets. A power-on LED indicator
shall be provided to indicate power-applied status.
PCMCPU - Central Processing Module. One PCMCPU module
shall be provided for the first nine (9) zones in the system. One
PCMCPU module shall be needed for each satellite system.
The module shall provide for satellite system identification via
built-in DIP switches. It shall include a locking program/run
selector switch (with program LED), satellite data link RCA
jack, and 12V DC power source jack. A connector block, using
screw terminal connections, shall be provided for paging
amplification connection, low-power and high-power BGM
connections, emergency/shift change signal activation, AUX
contact closure, and 12V DC power source connection. A
power-on LED indicator shall be provided to indicate power-
applied status.
PCMZPM - Zone Paging Module. One PCMZPM module shall
be provided for each three (3) paging zones in the system. Up
to three (3) PCMZPM modules may be connected to the mas-
ter system, for a total zone capacity of 9 zones. Up to three (3)
additional PCMZPM modules may be connected with a PCM-
CPU module to form a satellite system to further increase
zone capacity.
The PCMZPM module shall provide built-in DIP switches to
set talkback on/off for each zone. It shall include a power-on
LED, low-power background music volume control, back-
ground music out/in jumper field, local BGM selection
jumpers, and high-power/low-power operation selector switch.
A connector block, using screw terminal connections, shall be
included to connect local background music, zone wiring, and
relay driver outputs.
PCMTBM - Talkback Module. One PCMTBM talkback module
shall be provided per system (including any satellite systems).
The module shall provide for talkback operation in centrally-
amplified zones (only). The module shall provide a power-on
LED, talkback volume control, and talkback switching delay
control. A connector block, using screw terminal connectors
shall be included for paging amplification wiring.