Technical information
Remove cap then using a syphon! re-
move gasoline from tank.
.&.
WARNING: Gasoline is flamma-
T ble and explosive under certain
conditions. Always perform proce-
dures in a well ventilated area. Do
not
smoke or allow open flames or sparks
in
the
vicinity.
The carburetors
must
be dried
out
completely to prevent gum formation
during the storage period.
Assure that inlet fuel
line is discon-
nected.
Remove plug of the float chamber of
each carburetor. Drain carburetors.
Reinstall plugs and connect fuel lines.
Engine internal parts must be lubrica-
ted to protect cylinder walls from pos-
sible rust formation during the storage
period.
O
NOTE: This operation should be
repeated every 40 days during
storage.
Remove spark plugs. Operate rewind
starter
to bring piston at
top
position.
Pour the equivalent
of
one spoonful of
oil into spark plug hole.
Slowly crank engine several times
using manual starter. Repeat above
steps for other cylinder. Install spark
plugs .
...
CAUTION: To prevent ignition
• system damage, make sure
that
the
cut -out
button
is in
the
lower posi-
tion.
Inspection and cleaning should be per-
formed
by the dealer every 100 oper-
ating hours or at the end
of
each sea-
son, whichever occurs first.
IMPORTANT: The drive pulley assem-
bly will be excluded from warranty! if
the factory seal is broken
by other than
a duly authorized representative
of
Bombardier.
17