Owner's manual
Multi-Appliance Comfort Control
Controls- Installation / Setup / Commissionin
g
SETTING UP THE CONTROLS – DUCTED EVAPORATIVE AIR CONDITIONING
SETTING MINIMUM FAN SPEED
1. Using the MANUAL/AUTO button set the unit to MANUAL
2. Using the HEAT/COOL/FRESH AIR button set the unit to
COOL FRESH AIR
3. Adjust the fan speed to the minimum fan speed level and
press ENTER.
4. Press the ENTER and ECONOMY/ BOOST buttons together
for approximately 10 seconds pressing the ENTER button first.
5. The words FAN SPEED and a number under the room
temperature will flash.
6. Adjust minimum fan speed to a number suitable to the system
design. Ensure that the motor does not over-temp if setting the
fan speed lower.
7. Press ENTER to keep new fan speed.
SETTING MAXIMUM FAN SPEED
Maximum fan speed can only be access after the minimum fan
speed has been checked.
1. Using the MANUAL/AUTO button set the unit to MANUAL.
2. Using the HEAT/COOL/FRESH AIR button set the unit to
COOL FRESH AIR.
3. Using the ECONOMY/BOOST button set the unit to BOOST.
Press ENTER.
4. Press the ENTER and ECONOMY/ BOOST buttons together
for approximately 10 seconds pressing the ENTER button first.
5. The words FAN SPEED and a number under the room
temperature will flash.
6. Adjust maximum fan speed to 35 or a number to suit the
system design.
7. Press ENTER to keep new fan speed.
Setting the fan speeds to a low setting should be completed by an
authorised installer / service technician. Motor warranty may be
voided for incorrect settings.
Comfort Control - PNE
Page 43