Operating instructions
98  Application manual Positioning  04/08
4.8.3.1 Move away from SW limit switches 
The axis can be moved to the defined travel range again: 
−
Acknowledge error and move in opposite direction in JOG mode or 
− Acknowledge error and start positioning in opposite direction 
Error "F1444 Pos. SW-Lim. Switch < Neg. SW-Lim. Switch" is displayed if parameters 
Positive SW Limit Switch 1145 and Negative SW Limit Switch 1146 are set such 
that the positive SW switch is to the left of the negative SW switch. The value of the 
positive SW switch must be greater than the value of the negative SW switch. 
If the axis is at the position of a software limit switch, the corresponding direction of 
rotation of the drive is disabled. If you try to move in this direction, error message 
"F1451 Clockwise Operation Locked" or "F1452 Anticlockwise Operation Locked" will 
be displayed. 
Application manual Positioning 04/0898