4.8.6 Warning mask Application 
The logic signals of monitoring and control functions can be selected via parameter 
Create Warning Mask 536. For the available options, refer to the operating instruc-
tions. The logic signals of different positioning monitoring functions can be selected 
via parameter 
Create Appl. Warning Mask 626. As soon as limit switches are 
reached or contouring error thresholds are exceeded, a warning can be issued. The 
warnings refer to the parameter values set in error/warning behavior in configura-
tions x40. Depending on the application, any number of warnings can be configured. 
The warnings are selected via parameter 
Create Appl. Warning Mask 626: 
Create warning mask application 626
Function
0 -  No change 
The configured warning mask is not 
changed. 
2 -  Activate all Warnings 
The warnings reports stated are linked in 
the warning mask. 
10 -  Warning V-Belt 
Warning message of V-belt monitoring 
according to 
Operation Mode 581. 
11 -  Warning pos. SW limit switch 
Warning message indicating that the posi-
tive SW limit switch has been reached. 
12 -  Warning neg. SW limit switch 
Warning message indicating that the nega-
tive SW limit switch has been reached. 
13 -  Warning pos. HW limit switch 
Warning message indicating that the posi-
tive HW limit switch has been reached. 
14 -  Warning neg. HW limit switch 
Warning message indicating that the nega-
tive HW limit switch has been reached. 
15 -  Warning position controller 
Warning message, indicating that the con-
touring error monitoring range adjusted 
with parameter 
Warning Threshold 1105 
has been left. 
102 - 
Deactivate All 
Warnings 
All warnings are deactivated. 
110 -  Deactivate Warning V-Belt  No warning message of V-belt monitoring. 
111 - 
Deactivate warning pos. SW 
limit switch 
No warning when positive 
SW limit switch is reached. 
112 - 
Deactivate warning neg. SW 
limit switch 
No warning when negative 
SW limit switch is reached. 
113 - 
Deactivate warning pos. HW 
limit switch 
No warning when positive 
HW limit switch is reached. 
114 - 
Deactivate warning neg. HW 
limit switch 
No warning when negative 
HW limit switch is reached. 
115 - 
Deactivate warning position 
controller 
No warning message when contouring 
error monitoring range adjusted with pa-
rameter 
Warning Threshold 1105 has 
been left. 
Warning messages affecting the positioning functions can be displayed via parame-
ter 
Application Warnings 273 as actual values. 
In the error environment, 
Application Warning Status 367 indicates the current 
warnings of the positioning functions. 