Operating instructions
04/08  Application manual Positioning 13
3.3.1 Factory settings of the digital inputs 
Control input functions 
Digital
Input 
Control
terminal 
Control positioning  JOG mode / 
Teach-in 
Digital inputs of frequency inverter: 
S1IND  X210A.3  Digital input STOA for safety function 
S2IND  X210A.4  Start 
Positioning 
Store actual 
position value 
3)
JOG Clockwise 
S3IND  X210A.5  Stop Positioning, 
Touch probe 
1)
JOG Anticlockwise 
S4IND  X210A.6  Freely programmable or 
Encoder 1 Track B 
2) 
S5IND  X210A.7  Freely programmable or 
Encoder 1 Track A 
2)
S6IND  X210B.1  Home switch or 
Encoder 1 Zero Track Z 
2)
  X210B.2  Digital input STOB for safety function 
MFI1D  X210B.6  Change-over position con-
trol/JOG mode (JOG mode ac-
tive) 
Teach-in signal in teach-
in mode 
Digital inputs extension module: 
EM-S1IND  Motion Block Change-Over 1 
Alternative: - Encoder 2 Zero Track Z 
 - Fixed frequency change-over 1 
 - Fixed percentage value change-over 1 
EM-S2IND  Motion Block Change-Over 2 
Alternative: - Encoder 2 Track A 
 - Fixed frequency change-over 2 
 - Fixed percentage value change-over 2 
EM-S3IND 
depending 
on module 
Motion Block Change-Over 3 
Alternative: - Encoder 2 Track B 
1)
  Comply with the notes in section 4.4.1.3. 
2)
Dependent on the settings of parameters 
Configuration 30 and Operation
Mode
 490. See chapter 3.5.1.4. 
3) 
Switch on the function via parameter Operation Mode 1280. Comply with the 
notes in section 
4.13. 
Control terminal/   Description 
 Identification 
X210A.4  
  Start Positioning 
The input is assigned to parameter 
Start Positioning 1222. 
When activated, the 
Starting-Record Number 1228 or another 
motion block selected by the motion block change-over function 
is started. 
The motion blocks can be switched via digital inputs EM-S1IND, 
EM-S2IND and EM-S3IND of an extension module. 
  JOG Clockwise    In JOG mode, the drive is moved in positive direction (clockwise) 
at an adjustable fixed speed. JOG mode is activated via terminal 
X210B.6. In teach-in operation modes (
Operation Mode 1221), 
the JOG function is activated automatically. 
Store actual position 
value
The function can be switched on via parameter Operation Mode 
1280. With signal edge the actual position value is stored in the 
EEPROM and displayed via 
Latched Position 1281. 
Application manual Positioning 1304/08