Operating instructions
150  Application manual Positioning  04/08
5.5.3 Homing modes, only ref. signal and actual position
  Operation modes 33 and 34: Homing to first encoder ref. signal 
  Home position is the first encoder ref. signal in negative (operation mode 33) or 
positive (operation mode 34) direction. 
34
33
Encoder
reference signal
  Operation mode
35: Current position is home position 
  Current position is home position. Home offset (Parameter 1131) is taken over as 
actual position value. 
Actual position value
Home position
35
  Note:  Without encoder ref. signal, homing modes 1 to 14 as well as 33 and 34 
are not possible. 