Operating instructions
04/08  Application manual Positioning 25
3.5.4 Control via software 
All parameters of the frequency inverter can be set up via the PC software VPlus. In 
Configuration 30, set up an operation mode x40 which is suitable for positioning. 
Now, when data are read from the inverter, all parameters are read and are avail-
able for parameterization. 
With the PC software VPlus, 32 motion blocks with different motion profiles are 
available. The program VTable which is included in VPlus enables comfortable para-
meterization of the motion blocks. The program can be started via menu entry "Start 
Positioning" or the "Positioning Function" icon. VTable represents the 32 motion 
blocks arranged in columns, which provides better clarity. Via index 0, values can be 
changed for all motion blocks at the same time. This can be used, for example, to 
change the speed in all motion blocks quickly and comfortably. 
Application manual Positioning 2504/08