Attention!
− After changing motion profiles, you should test the automatic se-
quence of motion blocks at reduced speed. The scaled speed func-
tion can be activated via parameter 
Speed Override 1236. For the 
test, an emergency stop device must be provided in order to be able 
to stop the drive immediately in the case of extraordinary move-
ments. 
−
If the load moment is changed while motion blocks are being proc-
essed, the target position may not be reached. The deceleration va-
lue set in the motion block is too low in this case in order to stop the 
axis at the target position. 
Effective due to loa d
v
v
se tp o in t
param ete riz ed
t
Position
0
t
Target position
4.3.2 VTable
The control software VPlus enables access to the parameters of the frequency in-
verter. The additional program VTable which is included in VPlus enables easy and 
comfortable access to all 32 motion blocks at the same time. Motion blocks 1 to 32 
are entered in VTable via index 1 to 32. Index 0 can be used in order to set a value 
in all motion blocks at the same time. 
The parameters in the motion 
blocks perform one of three 
functions: 
[A] Target position incl. speed 
[B] Next motion block logic 
module 
[C]
Setting of digital signal 
The parameterized indices for 
Mux Input 1252 are independ-
ent from the motion block and 
can be used by the multiplexer 
for different digital signals [D]. 