Operating instructions
04/08  Application manual Positioning 55
4.4.2.3 Acceleration and Deceleration 
For parameters Acceleration 1204 and Deceleration 1205, the values for the mo-
tion to the target position are adjusted. 
Via the ramp rise time, a non-linear acceleration and deceleration (S-curve) can be 
obtained, and the load during acceleration and deceleration of the drive can be re-
duced, e.g. in order to limit jerking. The factory setting of 0 ms causes a linear 
ramp. 
Parameter Setting
No.  Description  Min.  Max.  Fact. sett. 
1204 Acceleration  1 u/s
2
 2
31
-1 u/s
2
  327 680  u/s
2
1205  Ramp Rise Time  0 ms  2000 ms  0 ms 
1206 Deceleration  1 u/s
2
 2
31
-1 u/s
2
  327 680  u/s
2
1207  Ramp Fall Time  0 ms  2000 ms  0 ms 
Speed
1203
Accelereation 
120
4
Deceleration 
1206
R
am
p
 Rise Time
1205
Ramp Fall Time
1207
t
4.4.2.4 Automatic sequence of motion blocks (next motion 
block)
In parameter configuration Operation Mode 1221 = 1xx (e.g. 101, 111, “Sequence 
Mode”), the positioning function enables an automatic sequence of motion blocks, 
i.e. when the target position is reached, the next target position is selected. The 
sequence control can be time-based (e.g. after a certain time has elapsed) or event-
oriented (e.g. via digital inputs or logic modules). 
The next motion block starts: 
− After expiry of a delay time: 
After expiry of 
Delay 1212 the motion block from Delay: Next Motion Block 
1213 starts. 
− After attaining a target position: 
Event 1 1214 starts the motion block from Event 1: Next Motion Block 1215.
Event 2 1216 starts the motion block from Event 2: Next Motion Block 1217. 
− After interruption of a running motion block: 
Interrupt-Event 1 1260 starts the motion block from Int.-Event 1: Next Motion 
Block
 1262. 
Interrupt-Event 2 1263 starts the motion block from Int.-Event 2: Next Motion 
Block
 1265. 
In that way logic-specific branches in the sequences can be parameterized. 
In the case of a relative positioning operation, the motion block can also be repeated 
via 
No. of Repetitions 1211. 
Application manual Positioning 5504/08