Set the next motion block, stop of the drive or error switch-off for an 
event:
By entering one of the listed values for parameters 
−
Delay: Next Motion Block 1213 
−
Event 1: Next Motion Block 1215 
−
Event 2: Next Motion Block 1217
−
Int.-Event 1: Next Motion Block 1262
−
Int.-Event 2: Next Motion Block 1265 
the next motion block or user-defined behavior in the case of events can be se-
lected. Errors in the motion sequence can be identified quickly by emergency stop, 
stop and the error switch-off function. 
Next motion block
1213, 1215, 1217, 
1262, 1265 
Function
-3 - 
(Minus 3) 
Em. stop, error 
The drive is stopped via 
Emergency Ramp 1179, 
after that, error message "F15XX User-Defined Error 
in Motion Block" is output. 
-2 - 
(Minus 2) 
Stop, error 
The drive is stopped at the active deceleration ramp, 
after that, error message "F15XX User-Defined Error 
in Motion Block" is output. 
-1 - 
(Minus 1) 
Error Switch-Off 
The drive is switched off, after that, error message 
"F15XX User-Defined Error in Motion Block" is out-
put. 
0 -  Disabled 
Factory setting. Processing of next motion blocks 
is switched off. 
1 … 32    The corresponding motion block is executed. 
Parameter Setting
No.  Description  Min.  Max.  Fact. sett. 
1214  Event 1  Logic signal or digital input  7 - Off 
1215  Event 1: Next Motion Block  -3  32  0 - Disabled 
1216  Event 2  Logic signal or digital input  7 - Off 
1217  Event 2: Next Motion Block  -3  32  0 - Disabled 
1260 
Interrupt
-Event 1 
Logic signal or digital input  7 - Off 
1261  Int.-Event 1: Eval.-Mode  1  6 
1 - Level 
Controlled 
1262  Int.-Event 1: Next Motion Block  -3  32  0 - Disabled 
1263  Interrupt-Event 2  Logic signal or digital input  7 - Off 
1264  Int.-Event 2: Eval.-Mode  1  6 
1 - Level 
Controlled 
1265  Int.-Event 2: Next Motion Block  -3  32  0 - Disabled 