Operating instructions
88  Application manual Positioning  04/08
Parameter Factory setting 
1128  Start Phasing  7 -  Off 
  Input and output signals of phasing function 
Phasing
Output si
g
nals
Start Phasing
1128
Phasing: Offset
Phasing: Speed
Phasing: Acceleration
1125
1126
1127
Signal source:
616 - Phasing Done
Operation modes for digital outputs:
56 - Phasing Done
156 - Inv. Phasing Done
Input si
g
nals
Assign digital input signals or 
logic signals to the parameter.
  Example of phasing function: 
1. Signal "Start Phasing" is set. 
2. Acceleration at "Phasing: Acceleration" to "Phasing: Speed". 
3. After offset by "Phasing: Offset", the digital signal "616 - Phasing Done" is set. 
The signal is available as operation mode "56 - Phasing Done" for digital outputs. 
Speed
Position
v
Master
Phasing: Acceleration
1127
Phasing: Offset
1125
Master position evaluated by the slave
physical master position
Phasing done
Start Phasing
Phasing: Speed
1126
Application manual Positioning 04/0888