Technical data
23
A drive with a PLC built in
The OS scans input and output buffers, samples 
input signals and executes output signals before it 
indexes the sequence of active modules.
As in any control panel PLC, cycle management 
is entrusted to the operating system and is 
independent of all other processes managed by 
the CPU.
The program is therefore deterministic and scan time 
proportional to the number of active function blocks.
In any automation process, the cycle period can be 
calculated by summing the 1-ms delays introduced 
by each function block.
Agile PLC functions can be programmed using 
VPlus software, which graphically displays the 
program to which the drive’s memory corresponds 
in real time.
VPlus software also provides a page that can be 
used to load graphic function blocks and link them 
together to create complex logic networks for use 
by the drive.
The Agile PLC supports and processes all the 
variables used by the drive software, including I/O 
variables, strings exchanged over the field bus and 
numeric motor control values. The PLC is therefore 
perfectly able to exchange signals with external 
devices like sensors, actuators, inverters, PLCs, PC’s, 
etc.) as well as with the drive itself.
External 
devices
Motor
control
routine 
Agile
I/O
PLC area
Field bus
External 
devices
Input Latches & Output Latches
Active function blocks
Inactive 
function blocks
Instructions
Function
block 1
I = 1
Function
block 2
I = 2
Function
block 3
I = 3 I = 4
P1343 = 0
Write
output buffer
Update
input buffer
24xx
25xx
20xx
23xx
1. ms
5. ms
...
2. ms
6. ms
...
3. ms
7. ms
...
4. ms
8. ms
...
(Return)
CYCLE