Technical data
30
General technical data
Environment
•Transportandstoragetemperature-25°C…55°C
•Operationtemperature:0°C-40°C(40°C-55°C
with derating)
•Environmentclass:3K3(EN60721-3-3)
•Relativehumidity5%...95%,nocondensation
•Altitudeofinstallation:upto3000m(over1000m
with derating)
•Storageconditions:accordingtoEN50178
•Degreeofprotection:IP20
Electrical
•
Ratedmainsvoltage3ph:intherange323….528V
•
Ratedmainsvoltage1ph:intherange200….240V
•Ratedmainsfrequency:intherange45…69Hz
•Overloadcurrent:150%nominalcurrent
•Peakcurrent:200%nominalcurrent
•Electricprotections:shortcircuit/earth
•Brakingtransistor:built-inonstandarddevice
Standards
•CEconformity:Lowvoltagedirective2006/95/EC
and EN50178 / DIN VDE 0160 and EN61800
•Interferenceimmunity:accordingtoEN61800-3
•ULapproval:accordingtoUL508c
•STO:61508/61800-5-2/13849
Connections 
The Agile drive is fitted with power input 
terminals for connection to the mains, power 
output terminals for driving the motor and signal 
terminals for inverter control, subdivided into four 
sections.
Power terminals
The power terminals are located at the top and 
bottom of the unit.
Mainsinputpowerisconnectedtothetopof
the drive where a DC-bus connection is also 
provided. The power output cables to the motor 
are connected to the bottom of the drive where 
there is also a connection for a braking resistance 
if required.
Just as on ACT and ACU drives, this effective 
separation of input and output power terminals 
helps prevent mis-wiring through human error.