Technical data
29
RS485 / CM-485
serial communication
The CM-485 communication module is designed for high speed data transmission over 
long distances in industrial applications. RS485 bus supports data exchange among 30 
nodes in a bidirectional 2-wires system.
The interface is based on a DB9 connector, following the standards for physical 
transmission of data ITU V.11 and ANSI EIA/TIA-422B
CM-485 communication card includes the end-of-line terminating resistor that can be 
activated or disconnected by means of an on-board dip switch.
The RS485 network address of the inverter is set by software parameters either via 
KP500controlunitorbymeansofPCinserialcommunicationwithKP-232.TheRS485
complies with ISO standard 1745 for code-bound data transmission. The standard data 
exchange rate and monitoring functions can be set using VPlus software.
Cable lenght Max Baud rate
up to 12000m 4.8
up to 2000m 19.2
Cable length limits the transmission 
bandwith. Above table shows the match 
between admissible cable lengths and 
corresponding max kBaud rates. Values are 
indicative and may significantly change 
in relation to the transmission cable 
characteristics.
CM-485 module
RS485 line
PC/Notebook
Location of CM-485 module on the 
frequency inverter