Technical data
54
Safe torque off (STO)
The safety function “Safe Torque Off” (STO) with 
the safety integrity level SIL 2 (see DIN EN 61508 
and DIN IEC 61800-5-2) is implemented into 
standard Active Cube inverter range.
The drive feature helps overall automation system 
to achieve “Safe Stop“ category 3, according to 
DIN EN 954-1.
Thanks to STO function, energy supply from 
frequency inverter to motor is safely disabled.
Deactivation of the inverter supply is carried out 
via two switch off paths in no-signal current mode, 
thus performing redundant switch off control. 
Continuous monitoring tests are done by the 
inverter to detect possible control failures. 
“Safe Torque Off“ function greatly improves safety 
level of your automation system without the need 
of additional components.
Safety Control
K
M
Off 2
Mains
Off 1 Integrated
safety function
Safety Control
K
M
Off 1 Off 2
Mains
Without STO
With STO