Operating instructions
08/06    37
4.11.5.1  Input parameters of the TxPDO’s for data to be 
transmitted 
T
he listed parameters can be used to stipulate the data that are to be transported
there for each position in the TxPDO tele
g
rams. The settin
g
 is done in such a way tha
t
a source number is entered for the required data in the parameters. 
TxPDO1 
Byte 
P. No. 
Boolean 
input 
TxPDO1 
Byte 
P. No. 
uint/int 
input 
TxPDO1 
Byte 
P. No. 
long input
 0  0  0 
1 
946 
Boolean1 
1 
950 
Word1 
1 
 2  2  2 
3 
947 
Boolean2 
3 
951 
Word2 
3 
954 
Long1 
 4  4  4 
 5 
948 
Boolean3 
5 
952 
Word3 
5 
 6  6  6 
 7 
949 
Boolean4 
7 
953 
Word4 
7 
955 
Long2 
TxPDO2 
Byte 
P. No. 
Boolean 
input 
TxPDO2 
Byte 
P. No. 
uint/int 
input 
TxPDO2 
Byte 
P. No. 
long input
 0  0  0 
1 
956 
Boolean1 
1 
960 
Word1 
1 
 2  2  2 
3 
957 
Boolean2 
3 
961 
Word2 
3 
964 
Long1 
 4  4  4 
 5 
958 
Boolean3 
5 
962 
Word3 
5 
 6  6  6 
 7 
959 
Boolean4 
7 
963 
Word4 
7 
965 
Long2 
TxPDO3 
Byte 
P. No. 
Boolean 
input 
TxPDO3 
Byte 
P. No. 
uint/int 
input 
TxPDO3 
Byte 
P. No. 
long input
 0  0  0 
1 
966 
Boolean1 
1 
972 
Word1 
1 
 2  2  2 
3 
967 
Boolean2 
3 
973 
Word2 
3 
976 
Long1 
 4  4  4 
 5 
968 
Boolean3 
5 
974 
Word3 
5 
 6  6  6 
 7 
969 
Boolean4 
7 
975 
Word4 
7 
977 
Long2 
  Note:  Dependin
g
 on the selected data information the percenta
g
es values are
displayed via the uint/int inputs. 