Specifications
15 
4.4 Setting Operation  
. Load Control Settings 
1. Dusk to Dawn (Light ON+Light OFF) 
When  solar  module  voltage  goes  below  the  point  of  NTTV  (Night  Time 
Threshold  Voltage)  at sunset, the  solar  controller  will recognize  the  starting voltage 
and turn on the load after 10 minutes delay; When solar module voltage  goes above 
point of DTTV (Day Time Threshold Voltage), the solar controller will recognize the 
starting voltage and turn off the load after 10 minutes delay.  
2. Light ON + Timer (1-15h hours on) 
When  solar  module  voltage  goes  below  the  point  of  NTTV  (Night  Time 
Threshold  Voltage)  at  sunset;  the  solar controller  will  recognize  the  starting  voltage 
and turn on the load after 10 minutes delay for several hours which users set on the 
timer. The timer setting operation is referred to as ―Load Work Mode Setting‖. 
3. Test mode 
It is used to test the system and the same as Dusk to Dawn.  But there is no 10 
minutes delay when controller recognizes the starting voltage. When below the starting 
voltage, the controller will turn on the load, if  higher,  it will  turn off load.  The test 
mode makes it easy to check the system installation. 
4. ON/OFF mode 
This mode is to turn on/off the load by Setting Switch 
. Load Work Mode Setting 
 Setting Indicator       Load Working Mode 
Setting Switch 
Figure 4-4 Instruction figure on setting 