Specifications
18 
·Load Short Circuit 
Fully protected against load wiring short-circuit. After two automatic load 
reconnect attempts (10 seconds between each attempt), the fault must be cleared by 
removing and reapply power. 
·High Voltage Input 
If the solar input open circuit voltage (Voc) exceeds the maximum input voltage 
of TRACER (TRACER 1206/60VDC; TRACER 1210/100VDC; 
TRACER 1215/150VDC), the array will remain disconnected until the Voc falls safely 
below the maximum rating. 
·PV Reverse Polarity 
Fully protection against PV reverse polarity, no damage to the controller will 
result. Correct the miswire to resume normal operation. 
·Battery Reverse Polarity 
Fully protection against battery reverse polarity, no damage to the controller will 
result. Correct the miswire to resume normal operation. 
·Damaged Internal Temperature Sensor 
If the temperature sensor short-circuited or damaged, the controller will be 
charging or discharging at the default temperature 25℃ to prevent the battery damaged 
from overcharging or over discharged. 
·High-Voltage Transients 
Solar, battery, and load power connections are protected against high voltage 
transients. In lightning prone areas, additional external suppression is recommended. 