Specifications
19 
5.2 Troubleshooting 
Troubleshooting according to the following instructions: 
Faults 
Possible reasons 
 Troubleshooting 
Charging LED indicator 
is off during daytime 
and sunshine falls on 
PV modules properly. 
PV array disconnection 
Check  that  PV  and  battery  wire 
connections are correct and tight. 
Green  charging  LED 
indicator is fast flashing 
Battery voltage higher 
than  over  voltage 
disconnection 
voltage(OVD) 
Check  if  battery  voltage  Over  high. 
Disconnect the solar module 
Battery and load 
LED indicators are 
Yellow color 
Battery under voltage 
Load  output  is  not  affected, charging 
LED  indicator  will  return  to  green 
automatically when fully charged. 
Battery  and  load LED 
indicators  stay  on RED 
color, and  loads are not 
working. 
Battery   
over discharged 
The  controller  will  cut  off the  output 
automatically,  LED  indicator  will 
return  to  green  automatically  when 
fully charged. 
Battery  and  load  LED 
indicators  are  RED 
slowly flashing. 
Load  power  exceeds 
rated power 
Remove some loads, then 
press the power switch, 
the controller will return to work after 
3 seconds,. 
Battery  and  load  LED 
indicators  are  RED  fast 
flashing 
Load  power  exceeds 4 
times of rated power or 
load short circuit. 
Check load connections and cut off the 
trouble loads, press the switch button 
once, output will be recovered  after 3 
second. There  is one time reconnect 
attempt  after  10  seconds  when  first 
time  short  circuit.  If  short  circuit 
occurs twice  continuously,  only  press 
the switch button can recover output. 
Table 5-1 Troubleshooting 
Note:If no LED indications 
With a multi-meter, measure the battery voltage at the battery terminal, it can 
only be powered when the battery voltage is over 9V. 