Specifications
6 
NOTE: The TRACER is a negative ground controller. Any combination of 
negative connections can be earth grounded as required. Grounding is     
recommended. 
CAUTION: Don’t connect DC-to-AC inverter to the TRACER directly because 
the peak current of the inverter may exceed rated current of the controller when     
the load turns on and will initiate short circuit protection. 
CAUTION:  The  total  current  draw  of  all  system  loads  connected  to  the 
TRACER LOAD terminals cannot exceed the 10A load current rating. All the     
loads surging current cannot exceed the 35A load current rating. 
CAUTION: For  mobile applications, be sure to secure all wiring. Use  cable 
clamps to prevent cables from swaying when the vehicle is in motion. Unsecured 
cables create loose and resistive connections which may lead to excessive heating   
 and/or fire. 
Step 1: Load Wiring 
The TRACER load output can connect lights, pumps, motors, and other electronic 
devices connection etc., TRACER will provide battery voltage to the loads. See 
Section 4.4 Setting Operation for more details about the load control. 
Figure 3-2 Load wiring 