Installation Guide

EN
16
Technical data
www.bora.com
Device dimensions CKG
327 
131 240 
 515 
Fig. 3.20  CKG device dimensions top view
 246 
 299 
 40,5 
 14 
 25 
 73 
 37 
Fig. 3.21  CKG device dimensions front view
487
485
14
15
Fig. 3.22  CKG device dimensions side view
3.7  CKG
Parameter Value
Supply voltage 220-240 V
Frequency 50/60 Hz
Total burner output 5.0 kW
Power rating 20 W
Fuse protection 1 x 0.5 A
Dimensions (width x depth x height) 
cooktop pan support high-power burner 
pan support normal burner
327 x 515 x 73 mm 
270 x 270 x 25/50 mm 
235 x 235 x 25/50 mm
Weight (incl. accessories/packaging) 11.5 kg
Cooktop
Power levels 1 – 9, P
Warming levels 3
High-power front burner 800 – 3000 W
Normal rear burner 550 – 2000 W
Total nominal connection values 
G20/20 mbar:
5.00 kW 0.449 m³/h
Cooktop energy consumption G20/20 mbar 
Category I2H 20 mbar 
(measurement taken without cooktop extractor)
High-power front burner 800 – 3000 W 63.3 %
Normal rear burner 550 – 2000 W 61.3 %
Total (average) 62.3 %
Tab. 3.7  Technical data