Installation Guide

EN
21
Installation
www.bora.com
2
1
Fig. 4.6  Plinth area air supply
[1]  Optional cable protection (shortened)
[2]  Airsupplyviatheplintharea(openingcross-section≥
150 cm²)
INFO  To ensure a sufficient air supply, an opening 
cross-section of at least 50 cm² is recommended 
in the front of the kitchen unit, or an opening 
cross-section of at least 150 cm² in the plinth 
area.
 Make sure that the area below the cooktop has a 
sufficient air supply.
4.5  Cut-out dimensions
INFO  All dimensions from the front edge of the front 
cover.
Worktop overhang
≥50x
Fig. 4.7  Worktop overhang
 Please note the worktop overhang x when creating 
the worktop cut-out. Applies to flush installation and 
surface mounting.
INFO  The hose line must not come into contact with hot 
surfaces on the cooktop or other devices.
INFO  The gas hose must be inspected every 5 years 
and replaced if necessary. The gas hose must 
meet the requirements of EN14800.
INFO  If the gas cooktop is used in a model with two 
cooktop extractors, it is to be installed at the side. 
If installed between the cooktop extractors, the 
pull of air on both sides may affect the flames.
Air supply to gas cooktop CKG
1 2
Fig. 4.5  Air supply at front of the body
[1]  Air supply via the front of the body (opening cross-section 
≥50 cm²)
[2]  Optional cable protection (shortened)