Installation Guide

EN
32
Installation
www.bora.com
INFO  If external switching devices are connected both 
to the Home In and Home Out interfaces, both 
cables should be secured with the strain relief 
clamp.
 Check the correct installation, as well as the firm 
positioning of the connection cables.
 Close and secure the control unit cover.
 Screw down the lid with the screw provided (max. 2 
Nm).
 Make sure that the cable is not damaged or trapped.
4.13  Establishing communication and 
power connection
INFO  The cooktops of the BORA Classic 2.0 system can 
only be operated with the central operating unit of 
the cooktop extractor CKA2.
INFO  The communication link between the cooktop 
extractor and cooktops is established via the 
control lines of the central operating unit.
INFO  The cooktops have their own electricity supply. 
This must be connected during installation.
INFO  The central operating unit is supplied with 
electricity by the communication cable.
11 10
15
16
14
1
5
4
4
2
2
1
3
7
8
9
6
1312
Fig. 4.38  Connection diagram for cooktop extractor CKA2
[1]  Cooktop mains cable
[2]  Power supply per cooktop
[3]  CAT 5e communication cable
[4]  CAT 5e cooktop communication cable
[5]  USB interface
[6]  Control unit mains cable (country-specific)
[7]  Control unit power supply
[8]  Fan 1 mains cable
[9]  Fan 1 control cable
[10]  Fan 2 mains cable
[11]  Fan 2 control cable
[12]  Home Out connection
[13]  Home In connection
[14]  Home In connection cable
[15]  External device
[16]  Power supply cable for external device
[M]  Fan 2
[S1]  External switch contact
4.13.1 Establishing contact between the 
cooktop extractor and cooktops
 Only use the cables supplied in the scope of delivery.
45
1 2 3
Fig. 4.39  Connecting the control cables to the cooktops
[1]  Left cooktop
[2]  Cooktop extractor
[3]  Right cooktop
[4]  Right cooktop control cable (R)
[5]  Left cooktop control cable (L)
 Connect the cooktop extractor control cables to the 
adjacent cooktops. 
 Ensure that each cable is connected to the correct 
socket.
The right angle connectors of the control cables are 
labelled L (left) and R (right).
4.13.2 Fitting split ferrite sleeves
INFO  The cooktop extractor connection cable must 
be filtered with a ferrite sleeve for reasons of 
electromagnetic compatibility. 