Installation Guide

EN
37
Installation
www.bora.com
If all cooktops have been recognised correctly:
 Carry out the basic configuration.
4.15.1 Function test
 Carry out a thorough function test on all devices.
 In the event of error messages, see the 
“Troubleshooting” chapter in the operating 
instructions.
Function test on gas cooktop CKG
 Switch the cooking zone on.
The electronic gas regulator will calibrate itself (humming 
noises) and then the gas flame will automatically ignite in 
the selected cooking zone.
The gas flame will burn steadily and evenly.
Using the gas cooktop together with the 
cooktop extractor for the first time
 Switch the cooktop extractor to the maximum power 
level.
 Switch all cooking zones to the minimum power level.
The electronic gas regulator will calibrate itself (humming 
noises) and then the gas flame will automatically ignite in 
the selected cooking zone.
The gas flame will burn steadily and evenly (no reignition). 
The gas flame will be slightly affected by the cooktop 
extractor (airflow) – this is normal.
INFO  If the gas flame goes out, is excessively affected 
by the extractor and/or the flame is not as it 
should be (e.g. soot production, flame blowback, 
etc.), the characteristic curve must be increased, 
as well as the ventilation in exhaust air mode, 
if necessary, or the return flow aperture in 
recirculation mode.
Faults when using gas cooktop CKG for the 
first time
When operating for the first time or after a prolonged 
period without use or when the liquid gas bottles have 
been changed, faults are possible:
The burner does not ignite.
There may be air in the gas pipe.
 Repeat the ignition process.
The burner does not ignite and the cooktop does not 
react.
The electronic gas regulator must be recalibrated.
 Using the gas configuration menu,
reset the gas 
regulator.
4.16  Sealing the devices
1
Fig. 4.48  Siliconesealantforushinstallation
[1]  black, heat-resistant silicone sealant
1
Fig. 4.49  Silicone sealant for surface mounting
[1]  black, heat-resistant silicone sealant 
 Once all of the installation work and initial operation is 
complete, seal the devices all around with black, heat-
resistant silicone sealant (also between the cooktop 
extractor and cooktop) [1].
 Make sure that no silicone sealant gets under the 
cooktop.
4.17  Handover to user
Once installation is complete:
 Explain the main functions to the user.
 Explain all safety-related aspects of operation and 
handling to the user.
 Affix the identification plates provided to the 
penultimate page in the operating instructions (see 
Operating instructions, Identification plates chapter).
If a CKG gas cooktop is installed: 
 also affix the nozzle set nameplate to the inside of 
the back cover of the CKG gas cooktop operating 
instructions.
 Provide the user with the accessories and operating 
and installation instructions, which are to be kept in a 