User Manual
EN
16
Installation
www.bora.com
Attaching the sealing tape
1
2
Fig. 6.7 Sealing tape with ush installation
[1] Black, heat-resistant silicone sealant
[2] Sealing tape
2
1
Fig. 6.8 Sealing tape with surface mounting
[1] Black, heat-resistant silicone sealant
[2] Sealing tape
With surface mounting, attach the enclosed sealing
tape [2] to the underside of the device before installing
it. Do not leave any gaps.
With flush installation, attach the enclosed sealing tape
to the horizontal cutting edge in the worktop cut-out,
even if you seal the cooktop with a silicone sealant [1]
or similar.
Stick the supplied nameplate (adhesive label) to the
back of your operating and installation instructions.
6.5 Installing the extraction system
INFO Clearance of one millimetre should be planned
between the built-in appliances.
INFO A clearance of two millimetres should be
planned around the built-in appliances.
Surface mounting
x
B ±2
≤ R5
≥ 50
495 ±2
≥ 600
≥ 50
Fig. 6.5 Surface mounting
10
10 – 40
Fig. 6.6 Surface mounting cut-out
Cut-out dimensions when installing cooktops only or cook-
tops and the BORA cooktop extractor alongside each other:
Cooktops/cooktop extractor B in mm
1/0 320
2/0 661
3/0 1002
2/1 752
3/2 1184
4/2 1525
Tab. 6.3 Cut-out dimensions