User's Manual
EN
24
Installation
www.bora.com
 Turn the angled ducting piece [1].
 Push the rotated angled ducting piece [1] back onto 
the ducting piece adapter [2] until the fastening lugs 
click into place.
Fig. 6.29  Airow to the left with angled ducting piece
 Make sure that no air gap has formed between the 
components.
 Secure the holding plate.
Rotate the cover frame about 180°.
INFO  In order to correct the direction of the cover 
frame, it may need to be rotated around 180°. 
Fig. 6.30  Dismounting the cover frame
 Rotate the cooktop extractor and place it down 
 carefully with the visible surface on a soft surface 
(e.g. a blanket).
 Carefully undo the holding clamps (18x) with a 
screwdriver.
2
1
Fig. 6.27  Mounting the straight ducting piece
[1]  Straight ducting piece
[2]  Ducting piece adapter
 Push the straight ducting piece [1] onto the ducting 
 piece adapter [2] until the fastening lugs click into 
place.
 Make sure that no air gap has formed between the 
components.
 Secure the holding plate to the ducting piece adapter 
[2] with just 2 screws.
6.7.2  Airflow to left  
(installation rotated around 180°)
INFO  The PKA cooktop extractor can be fitted rotated 
around 180° so that the airflow is to the left.
Airflow to the left with angled ducting piece
 Dismount the holding plate and the angled ducting 
piece (see Airflow straight to the side).
 Rotate the cover frame around 180° 
(see Rotating the cover frame around 180°).
2
1
Fig. 6.28  Turn angled ducting piece
[1]  Angled ducting piece
[2]  Ducting piece adapter