User Manual
EN
11
Technical data
www.bora.com
3 Technical data
Appliance dimensions
R3
370
133,5 255,5
540
Fig. 3.1 PKG3 appliance dimensions from above
246
341
62
14,5
7
25
73
37
Fig. 3.2 PKG3 appliance dimensions front view
491
509
15,5
24,5
240
Fig. 3.3 PKG3 appliance dimensions side view
3.1 BORA Pro gas cooktop PKG3
Parameter Value
Supply voltage 220–240V
Frequency 50/60Hz
Total burner output 5.0kW
Power rating 20W
Fuse protection 1 x 0.5A
Gas connection 1/2“ internal thread
Dimensions (width x depth x height)
cooktop
pan support high-power burner
pan support normal burner
370 x 540 x 73mm
270 x 270 x 25/50mm
235 x 235 x 25/50mm
Weight (incl. accessories/packaging) 11.5kg
Cooktop
Power levels 1–9, P
Heat retention levels 3
Front high-power burner 800–3000W
Normal rear burner 550–2000W
Total nominal connection values
G20/20mbar:
5.00kW
0.449m³/h
Cooktop energy consumption G20/20mbar
Front high-power burner 850 – 3000 W 60,0 %
Normal rear burner 700 – 2000 W 60,0 %
Total (average) 60,0 %
Tab. 3.1 Technical data
Additional technical data for Australia and New Zealand
(AUS/NZS):
Total nominal connection values for natural gas/
1.0 kPa test point pressure: 19.5 Mj/h
Cooktop energy consumption AUS/NZS natural gas/
1.00 kPa test point pressure:
High power front burner 12.0 Mj/h
Normal back burner 7.5 MJ/h