User Manual

EN
27
Installation
www.bora.com
Standard cooking zone connection
5 4
3
2
1
Abb. 5.32 Standard connection of appliances that connect at
the front
[1] Cooktop
[2] Rear cooking zone (zone 2)
[3] Front cooking zone (zone 1)
[4] Rear cooking zone control knob (zone 2)
[5] Front cooking zone control knob (zone 1)
Connecting the cooking zones when the cooktop is
installed rotated by 180°
5 4
3
2
1
Abb. 5.33 Connecting the cooking zones when the cooktop is
installed rotated by 180° and the ports are on the
front of the appliance
[1] Cooktop
[2] Rear cooking zone (zone 1)
[3] Front cooking zone (zone 2)
[4] Rear cooking zone control knob (zone 1)
[5] Front cooking zone control knob (zone 2)
X
Connect the port on the back of the left control knob [5] to
the “zone 2” port on the cooktop [1].
X
Connect the port on the back of the right control knob [4] to
the “zone 1” port on the cooktop [1].
X
Using the configuration menu, set the correct allocation of the
cooking zones in the control knob display (see “Configuration
menu” – “0° or 180° installation”).
5.9.2 Establishing contact between the
cooktop extractor and cooktops
ZONE1 INTERF. COM1 ZONE2
ZONE1 INTERF. COM1 ZONE2
4
3
1
2
Abb. 5.34 Establishing contact between the cooktop extractor
and cooktops
[1] Cooktop extractor communication cable port for left cooktop
[2] Cooktop extractor communication cable port for right cooktop
[3] Cooktop communication cable port
[4] Cooktop to cooktop extractor
X
Using the communication ports provided, connect the
cooktop extractor [1]/[2] to the cooktop or cooktops [3].
X
Only use the cables supplied in the scope of delivery.
i
The full range of functions on the appliances will only
be available if the cooktop extractor and cooktops are
connected correctly.
5.9.3 Connecting the power supply
i
Assembly, installation and commissioning must always
occur in line with national laws, regulations and
standards.
i
The work must be performed by qualified specialists who
know and comply with the additional regulations of the
local energy supply companies.
i
The appliances may only be connected to the mains
power supply by certified specialists. The specialist also
assumes responsibility for the proper installation and