User Manual

EN
29
Installation
www.bora.com
Faults during initial operation
When operating for the first time or after a prolonged period
without use or when the liquid gas bottles have been changed,
faults are possible:
The burner does not ignite. The control knob emits an
acoustic signal and the power level display flashes.
There may be air in the gas pipe.
X
Try to ignite it again by touching the control knob.
The burner does not ignite and the cooktop does not
react.
The electronic gas regulator must be recalibrated.
X
Using configuration
Ch,
reset the gas regulator.
The control knob display shows an error message (e.g.
E001).
X
Using configuration
Ch,
reset the gas regulator.
5.12 Function test
X
Carry out a thorough function test on all appliances in
accordance with se„5.11.1 Using the gas cooktop for the first
time“me”
X
In the event of error messages, see the “Troubleshooting”
chapter in the operating instructions.
5.13 Sealing the appliances
1
Abb. 5.36 Silicone sealant for ush installation
[1] Black, heat-resistant silicone sealant
1
Abb. 5.37 Silicone sealant for surface mounting
[1] Black, heat-resistant silicone sealant
X
Once all of the installation work and initial operation is
complete, seal the appliances all the way round (also between
the cooktop extractor and cooktop) with black, heat-resistant
silicone sealant [1].
X
Make sure that no silicone sealant gets under the cooktop.
5.14 Handover to user
Once installation is complete:
X
Explain the main functions to the user.
X
Explain all safety-related aspects of operation and handling to
the user.
X
Affix the supplied nameplate to the back of these instructions.
X
Provide the user with the accessories and all accompanying
documents, which are to be kept in a safe place.