Installation and Operation Guide

EN
15
Device description
www.bora.com
Power level Switch off after hours:minutes
1
08:24
2
06:24
3
05:12
4
04:12
5
03:18
6
02:12
7
02:12
8
01:48
9
01:13
P
00:10
Tab. 4.6 Safety shut-down for power levels
Heat retention level Switch off after hours:minutes
1 (
,
)
08:00
2 (
:
)
08:00
3 (
*
)
08:00
Tab. 4.7 Safety shut-down for heat retention levels
Switch the cooking zone back on (see Operating
section) if you want to put the cooking zone back
into operation.
4.4.3 Overheating protection
The device is fitted with overheating protection.The
overheating protection can be triggered if:
Cookware is heated up empty.
Oil or fat is heated on high power.
A hot cooking zone is switched on again after a power cut.
There is insufficient ventilation below the cooktop (see
Cooktop air intake).
Before the overheating damages the electronics, one of
the following measures is taken:
The power level can no longer be increased.
The power level set is reduced.
The cooktop switches off completely.
After a sufficient cooling period, the cooktop can be used
again in full.
4.4.4 Childproofing feature
The childproong feature prevents the cooktop from
being switched on accidentally.
L
is displayed.
The childproong feature can only be activated when all
the cooking zones are switched o (see the Operation
section).
4.3.7 Timer functions
There are two different timer functions for each cooking
zone.
t
appears in the control knob display.
INFO You can set a time range of between 1 and
120 minutes for the timer functions.
Timer function
INFO The timer function is an automatic cut-off
which automatically switches off a cooking
zone which is in use.
Short-time timer (egg timer)
INFO The short-time timer requires the cooking
zone to be switched off and works like a
conventional egg timer.
4.3.8 Pause function
The cooking session can be temporarily interrupted (max.
10 minutes).
1
1
is displayed.
4.4 Safety devices
4.4.1 Residual heat display
INFO While
H
is displayed (residual heat display),
do not touch the cooking zone or place any
heat-sensitive objects on top of it.
Risk of burns and fire!
After switching it off, the cooking zone remains hot.
H
is displayed in the control knob display (residual heat
display). The display goes out after a sufficient cooling
time (temperature < 60 °C).
4.4.2 Safety shut-down
Each cooking zone is switched off automatically when the
cooking zone in the power level or heat retention level
exceeds the maximum operating duration.
H
is displayed
(residual heat display).