6.4.3  Automatic heat up function
When the automatic heat up function is activated, the cooking 
zone works at full power for a certain time and is then 
automatically reset to the previously set level. 
The system automatically determines the heating time 
depending on the power level set.
PKI3
Power level (continuous cooking 
level)
Cooking times in min:sec
1
00:40
2
01:00
3
02:00
4
03:00
5
04:20
6
07:00
7
02:00
8
03:00
Tab. 6.4  Overview of heating times
 i
If the cooking zone power level is increased while the 
automatic heat up function is active, the automatic heat 
up function remains active. The heating time is adjusted 
accordingly. 
 i
If the cooking zone power level is decreased while the 
automatic heat up function is active, the automatic heat 
up function is deactivated.
Requirement for the automatic heat up function:
XO
cooking session with a power level between 1 and 8.
Activating the automatic heat up function
XX
Open the cooktop function menu.
XX
Do the following:
1
2
3
4
Fig. 6.16  Activating the automatic heat up function
XO
An acoustic signal is heard, the automatic heat up function is 
activated and the corresponding timer counts down. 
XO
The heat-up symbol 
A
 and the set power level are shown in 
the control knob display (e.g. 
A
5
).
Deactivating the automatic heat up function early
The activated automatic heat up function will end prematurely if 
you
XX
reduce the power level (continuous cooking level);
XX
set the power level 
9
;
XX
activate the power setting 
ßp
;
XX
activate the heat retention level 
v
;
XX
switch off the cooktop.
Time lapsed
XO
When the heat up time has lapsed, the previously set 
continuous cooking level will be activated.
XO
An acoustic signal is heard.
XO
The heat up symbol will no longer be displayed